SG 04.2
SG 10.2
with actuator controls MEC 03.1
7.2.
Switch compartment: open/close
Open
Close
Figure 18:
The following sub-assemblies are located within the switch compartment:
End position detection
RWG electronic position transmitter (option)
Mechanical position indicator
The switch compartment must be opened to perform the setting of these
sub-assemblies.
1.
Loosen screws [2] and remove cover [1] from the switch compartment.
2.
Clean sealing faces of housing and cover.
3.
Check whether O-ring [3] is in good condition, replace if damaged.
4.
Apply a thin film of non-acidic grease (e.g. petroleum jelly) to the O-ring and
insert it correctly.
5.
Place cover [1] on switch compartment.
6.
Fasten screws [2] evenly crosswise.
Commissioning
21