Sign In
Upload
Manuals
Brands
AUMA Manuals
Controller
SAEx Series
AUMA SAEx Series Manuals
Manuals and User Guides for AUMA SAEx Series. We have
2
AUMA SAEx Series manuals available for free PDF download: Operation Instructions Manual, Manual
AUMA SAEx Series Operation Instructions Manual (104 pages)
Multi-turn actuators, Control unit: electronic (MWG) with actuator controls, ACExC 01.2 Non-Intrusive
Brand:
AUMA
| Category:
Controller
| Size: 2 MB
Table of Contents
Table of Contents
2
1 Safety Instructions
5
Prerequisites for the Safe Handling of the Product
5
Range of Application
5
Warnings and Notes
6
References and Symbols
6
2 Identification
8
Name Plate
8
Short Description
11
3 Transport and Storage
13
Transport
13
Storage
15
4 Assembly
16
Mounting Position
16
Valve Attachments
16
Design of Output Drive Type a
16
Design of Output Drive Types B and E
17
Handwheel Fitting
17
Actuator: Mount to Valve
18
Stem Nut for Output Drive Type A: Finish Machining
18
Multi-Turn Actuator with Output Drive Type A: Mount
20
Multi-Turn Actuator with Output Drive Type B: Mount
21
Accessories for Assembly
22
Stem Protection Tube for Rising Valve Stem
22
Mounting Positions of Local Controls
23
Mounting Positions: Modify
24
5 Electrical Connection
25
Basic Information
25
KL Electrical Connection
28
Terminal Compartment: Open
29
Cable Connection
30
Profinet Cables: Connect
34
Terminal Compartment: Close
35
External Earth Connection
36
Accessories for Electrical Connection
37
Actuator Controls on Wall Bracket
37
Parking Frame
38
Operation
39
Manual Operation
39
Manual Valve Operation
39
Motor Operation
40
Operating the Actuator from Local Controls
40
Actuator Operation from Remote
41
Menu Navigation Via Push Buttons (for Settings and Indications)
41
Menu Layout and Navigation
42
User Level, Password
43
Password Entry
44
Password Change
44
Language in the Display
45
Language Change
45
Indications
47
Indications During Commissioning
47
Indications in the Display
47
Feedback Signals from Actuator and Valve
48
Status Indications According to AUMA Classification
50
Status Indications According to NAMUR Recommendation
51
Indication Lights of Local Controls
53
Optional Indications
54
Mechanical Position Indication (Self-Adjusting)
54
Mechanical Position Indication Via Indicator Mark (Not Self-Adjusting)
54
Signals (Output Signals)
55
Signals Via Profinet
55
Status Signals Via Output Contacts (Digital Outputs)
55
Assignment of Outputs
55
Coding the Outputs
55
Analogue Signals (Analogue Outputs)
55
Commissioning (Basic Settings)
57
Type of Seating: Set
57
Torque Switching: Set
58
Limit Switching: Set
60
Test Run
62
Direction of Rotation at Mechanical Position Indicator: Check
62
Direction of Rotation at Hollow Shaft/Stem: Check
64
Limit Switching: Check
64
Commissioning (Settings/Options in the Actuator)
66
Switch Compartment: Open/Close
66
Mechanical Position Indicator (Self-Adjusting)
67
Mechanical Position Indicator: Set
67
Gear Stage of the Reduction Gearing: Test/Set
68
Mechanical Position Indication Via Indicator Mark (Not Self-Adjusting)
69
Mechanical Position Indicator: Set
69
Gear Stage of the Reduction Gearing: Test/Set
70
Corrective Action
73
Faults During Commissioning
73
Fault Indications and Warning Indications
73
Fuses
77
Fuses Within the Actuator Controls
77
Fuse Replacement
78
Replace Fuses
78
Test/Replace Fuses
79
Motor Protection (Thermal Monitoring)
79
Servicing and Maintenance
81
Preventive Measures for Servicing and Safe Operation
81
Disconnection from the Mains
81
Maintenance
82
Disposal and Recycling
83
Technical Data
85
Technical Data Multi-Turn Actuators
85
Technical Data Actuator Controls
87
Spare Parts
93
Multi-Turn Actuators SA(V)Ex
93
Sa(V)Ex 16.2/SAR(V)Ex 07.2
93
Sar(V)Ex 16.2 KT/KM
93
Acexc 01.2 KL-Ex D Actuator Controls
95
Certificates
97
Declaration of Incorporation and EU Declaration of Conformity
97
Index
98
Addresses
101
Advertisement
AUMA SAEx Series Manual (52 pages)
Multi-turn actuators with actuator controls AC 01.2-SIL/ACExC 01.2-SIL
Brand:
AUMA
| Category:
Controller
| Size: 1 MB
Table of Contents
Table of Contents
2
1 Terminology
4
Abbreviations and Concepts
4
Sa 16.2/Sar 07.2
4
2 Application and Validity
6
Range of Application
6
Standards
6
Valid Device Types
6
Architecture (Actuator Sizing)
7
3 Architecture, Configuration and Applications
7
Configuration (Setting)/Version
8
Applications (Environmental Conditions)
9
Safety Functions
11
Safety Instrumented System Including an Actuator
11
4 Safety Instrumented Systems and Safety Functions
11
Redundant System Architecture
12
Safe Inputs and Outputs
12
Examples of Applications
13
System Representation
14
Installation
15
5 Installation, Commissioning and Operation
15
Commissioning
16
Decommissioning
17
Lifetime
17
Operation
17
6 Indications on Display
18
Status Indications on SIL Functions
18
Backlight
19
SIL Configuration Warning
19
7 Signals
20
Signals Via SIL Module
20
SIL Fault Signal Via Standard Controls Display (for Troubleshooting Support)
20
Signal Via Fieldbus of Standard Controls
21
Status Signals Via Output Contacts (Digital Outputs) of Standard Controls
21
Internal Actuator Monitoring with Control Via Standard Controls
23
Partial Valve Stroke Test (PVST): Execute
23
Safety Equipment: Check
23
Tests and Maintenance
23
Proof Test (Verification of Safe Actuator Function)
24
Safe ESD Safety Operation (Safe OPENING/CLOSING)
25
SIL Fault Signal "Actuator Monitoring": Check
26
Safe ESD Reaction for "Motor Protection (Thermal Fault)" Signals: Check
26
Safe ESD Reaction to "Limit Seating with Overload Protection
27
Safe ESD Reaction to "Forced Limit Seating in End Position" (Limit Evaluation) for Actu
29
Safe ESD Reaction for "Forced Limit Seating in End Position" (Limit Evaluation) for Actu
29
Safe ESD Reaction to "Forced Torque Seating in End Position
30
Safe ESD Reaction for "No Seating" (no Evaluation of Limit and Torque): Check
31
Safe STOP Function: Check
32
Combination of Safe ESD and Safe STOP Function: Check
33
Maintenance
34
Determination of the Figures
35
Safety-Related Figures
35
Specific Figures for AC 01.2 Controls in SIL Version with Actuators of SA.2 Series
36
SIL Certificate
39
Checklists
40
Commissioning Checklist
40
Proof Test Checklists
40
Safe ESD Safety Operation (Safe OPENING/CLOSING)
40
SIL Fault Signal "Actuator Monitoring
40
Safe ESD Reaction to "Motor Protection (Thermal Fault)" Signals
41
Safe ESD Reaction to "Limit Seating with Overload Protection
42
Safe ESD Reaction to "Forced Limit Seating in End Position" (Limit Evaluation) for Actu
42
Safe ESD Reaction to "Forced Torque Seating in End Position
44
Safe ESD Reaction to "No Seating
44
Safe STOP Function
45
11.2.10. Combination of Safe ESD and Safe STOP
46
Index
49
Addresses
50
Advertisement
Related Products
AUMA SAEx 07.6
AUMA SAEx 10.2
AUMA SAEx 14.6
AUMA SAEx 16.2
AUMA SAEx 14.2
AUMA SAExC 07.1
AUMA SAExC 10.1
AUMA SAEx 35.1
AUMA SAEx 07.2 KT/KM
AUMA A 25.2
AUMA Categories
Controller
Industrial Equipment
Control Unit
Control Systems
Outboard Motor
More AUMA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL