AUMA SG Series Operation Instructions Manual page 11

Part-turn actuators with actuator controls mec 03.1 marine version
Table of Contents

Advertisement

SG 04.2
SG 10.2
with actuator controls MEC 03.1
4.
Place coupling [1] onto valve shaft [2] and secure against axial slipping by using
a grub screw [3] or a clamping washer and a screw with curved spring lock
washer [4]. Thereby, ensure that dimensions X, Y or L are observed (refer to
figure and table <Mounting positions for coupling>).
Figure 8: Examples: Fit coupling
[1]
Coupling
[2]
Valve shaft
[3]
Grub screw
[4]
Clamping washer and screw with curved spring lock washer
Figure 9: Mounting positions for coupling
Table 2:
Mounting position of the coupling within fitting dimensions according to AUMA definition
Dimensions
SG 04.2
[mm]
EN ISO 5211
F07
X max
3
Y max
5
L max
35
5.
Apply non-acidic grease at splines of coupling (e.g. Gleitmo by Fuchs).
SG 05.2
SG 07.2
F07
F07
3
3
6
5
35
35
Assembly
SG 10.2
F07
3
10
35
11