AUMA SG Series Operation Instructions Manual page 33

Part-turn actuators with actuator controls mec 03.1 marine version
Table of Contents

Advertisement

SG 04.2
SG 10.2
with actuator controls MEC 03.1
Speed LOCAL
Speed REMOTE
Speed I/O interface
Table 11:
Beispielwerte zur Einstellung für Baugrößen SG 04.2/05.2/07.2
Output speed via parameter:
Speed LOCAL
Speed REMOTE
0.0 %
9.0 %
14.0 %
23.0 %
34.0 %
52.0 %
75.0 %
100.0 %
Table 12:
Example values for SG 10.2 size setting
Output speed via parameter:
Speed LOCAL
Speed REMOTE
0.0 %
10.0 %
17.0 %
26.0 %
40.0 %
57.0 %
85.0 %
100.0 %
Motor speed
Speed LOCAL
Speed REMOTE
Speed I/O interface
Description of parameters:
Output speed for operation via local controls (operation mode Local); Setting range:
linear between 0
100 % of max. motor speed; Default value = 50.0 %
Output speed in operation mode Remote for setting the parameter Speed I/O interface
= Internal ; Setting range: linear between 0
% = max. motor speed); Default value = 50.0 %
= External
In operation mode Remote, the output speed is defined via analogue input AIN 1 (4
20 mA).
= Internal
In operation mode Remote, the output speed is not defined via analogue input AIN
1 but via the Speed REMOTE software parameter.
Output speed via
AIN1
(Speed I/O interface
= External)
4
20 mA
4.0
5.4
6.3
7.7
9.5
12.3
16.0
20.0
Output speed via AIN1
(Speed I/O interface = External)
4
20 mA
4.0
5.5
6.7
8.1
10.4
13.2
17.6
20.0
Basic settings for the actuator controls
100 % (0 % = min. motor speed, 100
Speed
Motor
[rpm]
133
314
431
627
863
1,232
1,725
2,250
Speed
Motor
[rpm]
133
338
491
675
928
1,350
1,929
2,250
Operating time
Output drive
[s]
52
22
16
11
8
5.6
4
3.1
Operating time
Output drive
[s]
81
32
22
16
11
8
5.6
4.8
33