Variable Damper Test - Raven New Holland AutoBoom XRT Calibration & Operation Manual

Table of Contents

Advertisement

C
7
HAPTER

VARIABLE DAMPER TEST

This test allows the user to manually apply a control effort to the variable damper system.
1. Select Connectivity Test
2. Enter a Target Effort Percentage
3. Touch the Start button.
NOTE:
Each damper should draw between 2.0 and 2.8 amps when tested at 100%.
FIGURE 22. Variable Damper Test
66
New Holland AutoBoom XRT Calibration & Operation Manual