PRESETS CONFIGURATIONS

The Presets Configuration page allows the user to select the desired Preset Mode, select the number of Taps to
enable the mode, and also select if using the joystick will enable the mode.
Boom control switches can be configured to perform certain functions depending on the number of joystick
presses. For example, the user can configure the system to raise the boom to a higher position (e.g. for end of row
turnaround) when the switch on the joystick is quickly tapped up three times. To configure presets:
1. Navigate to Machine Settings > Preset Configuration.
2. Select the desired boom. Each boom will have it's own settings from each preset selected.
FIGURE 11. Preset Configuration
3. Select the desired Preset Mode.
a.
Spray Mode - Standard XRT operation mode
b. Preset 1 - User customizable mode
c.
Preset 2 - User customizable mode
4. Select the Trigger Method.
a.
There is one trigger method per Preset mode.
5. Select the Control To option.
a.
Height - The preset will control to a user selected height.
b. Angle - The preset will control to a user selected angle.
c.
Spray Height - The preset will control to the height in the Spray mode.
d. Transport - The preset will control to a max height and disable the wing when it reaches the height.
6. If desired, select the Joysticks check box. Selecting Joystick enables or disables joystick shortcuts for mode
changing.
7. To activate the preset, press the joystick button in the direction selected as the trigger type and press it the
number of times selected as number of taps.