FOLD TUNING

NOTE:
The following settings may also be configured through the New Holland armrest display. Refer to the
Boom Speed Settings section on page 23 for assistance with using the armrest display to configure
these values.
Fold Tuning displays fold settings based on machine configuration (Make, Model, Boom Width) options selected
during initial calibration. If needed, the user can adjust Sensitivity, Base Duty Cycle, and the Min/Max values.
1. Sensitivity can be set independently for Up/In and Down/Out. Higher sensitivities correspond to faster
movements during manual boom movement.
2. Base Duty Cycle (Lift Only) is the Duty Cycle required to hold the booms level/stationary. Changing this value
does not effect the equivalent value for AutoBoom.
3. Min and Max values set the maximum and minimum duty cycle that will be applied to the specified joint when
the system is AutoFolding In or Out. The Min/Max values do not affect manual folding operations.
NOTE:
These settings are only available for boom joints that have proportional hydraulic cartridges.
FIGURE 13. Preset Configuration
016-0235-010 Rev. B
SETTINGS
31