Using Manual Acquisition And Auto Acquisition Together; Setting Up The Automatic Acquisition/Activation Zone (Az) - JRC JMR-7230-S Instruction Manual

Marine radar equipment
Hide thumbs Also See for JMR-7230-S:
Table of Contents

Advertisement

Memo
If only the manual acquisition mode will be used without using auto acquisition/activation together,
disable the AZ.

6.5.1.3 Using manual acquisition and auto acquisition together

By using manual acquisition with AZ enabled, auto acquisition and manual acquisition can be used
together. They may be used if a target to which particular attention should be given is manually
acquired and other targets are automatically acquired.
6.5.2 Setting up the automatic
acquisition/activation zone (AZ)
Auto acquisition/activation zone has the shape of sector set up according to the angle and distance as
shown in the following figure.
AZ1
AZ2
Example of auto acquisition/activation zone (AZ)
Auto acquisition/activation zone (AZ) is set up using the following three methods.
(1) Use the [New Target Warning] dialog in the [Alert] menu.
(2) Use the cursor.
(3) Use the EBL/VRM dial.
Memo
Automatic activation only works for AIS targets inputted from AIS receiver.
End angle
Start angle
Start distance
End distance
6-23