Pepperl+Fuchs AS-I 3.0 Manual page 13

Command interface
Table of Contents

Advertisement

AS-i 3.0 Command Interface
List of all Commands
Values for command
see page Command
page 127
function 1E
page 129
function 1F
page 130 function 26
page 132 function 27
page 134
function 17
page 135
function 22
1.
There are improved versions of these commands. We don't recommend to use the old one any more.
2.
The command READ_FAULT_DETECTOR is valid only for the use with masters which support this function. Please
refer to the user manual of the master for further information.
3.
The command READ_DUPLICATE_ADDR is valid only for the use with masters which support this function. Please re-
fer to the user manual of the master for further information.
4.
The command GET_SLV_ERRCOUNT is valid only for the use with masters which support this function. Please refer
to the user manual of the master for further information.
5.
The command GETCLEAR_SLV_ERRCOUNT is valid only for the use with masters which support this function. Please
refer to the user manual of the master for further information.
6.
Der Befehl READ_REL_CYC gilt nur für Master, die diese Funktion unterstützen. Bitte schauen Sie im Handbuch des
Masters nach weiteren Informationen.
7.
Der Befehl MB_OP_GET_EXT_EF gilt nur für Master, die diese Funktion unterstützen. Bitte schauen Sie im Handbuch
des Masters nach weiteren Informationen.
8.
Der Befehl MB_OP_GET_LINE_ERRCOUNT gilt nur für Master, die diese Funktion unterstützen. Bitte schauen Sie im
Handbuch des Masters nach weiteren Informationen.
9.
Der Befehl MB_OP_GETCLEAR_LINE_ERRCOUNT gilt nur für Master, die diese Funktion unterstützen. Bitte schauen
Sie im Handbuch des Masters nach weiteren Informationen.
10. The command CROSS_COMMUNICATION_DIAG is valid only for the use with masters which support this function.
Please refer to the user manual of the master for further information.
11. The command REWRITE_DPRAM is valid only for the use with AS-i 3.0 Module OEM Master.
12. There are improved versions of these commands. We don't recommend to use the old one any more.
13. The command EXT_DIAG is valid only for the use with AS-i 3.0 PROFIBUS Gateways.
14. The command RD_EXT_DIAG is valid only for the use with AS-i 3.0 PROFIBUS Gateways.
15. There are improved versions of these commands. We don't recommend to use the old one any more.
Value Meaning
7E
16
7D
7E
16
7D
7E
16
7D
7E
16
7D
7E
16
7E
16
7D
read AS-i current maximal value
16
reset AS-i current maximal value
16
read AS-i current limit value
16
write AS-i current limit value
16
read ripple voltage maximal value
16
reset ripple voltage maximal value
16
read ripple voltage limit value
16
reset ripple voltage limit value
16
read S-7.5 slave information
16
read the type of power supply
16
write the type of power supply
16
Req
Res
Len
Len
3
4
3
2
3
3
4
2
3
6
3
4
3
4
4
2
4
7
3
3
4
2
Tab. 3-4.