Read Control Parameter (Mb_Op_Ctrl_Rd_Prm) - Pepperl+Fuchs AS-I 3.0 Manual

Command interface
Table of Contents

Advertisement

AS-i 3.0 Command Interface
Commands of the Command Interface
4.7.19

Read control parameter (MB_OP_CTRL_RD_PRM)

This command is used to read out 16 parameter bytes of a control program star-
ting at any start address for devices having control functionality.
Byte
1
2
3
4
1.
The address range for the parameter bytes extends from 0 to 1024. This means the value for the start
address can be maximum 1008.
Byte
1
2
3
...
18
7
6
5
2
2
2
T
7
6
5
2
2
2
T
Request
4
3
2
2
89
16
start address, low byte
start address, high byte
Response
4
3
2
2
89
16
result
data byte 1
...
data byte 16
2
1
2
2
1
1
Tab. 4-203.
2
1
2
2
Tab. 4-204.
0
2
0
2
105