DRP 7.23 Tray Sensor Assembly (PL22.2.29)
Use this procedure to remove and replace the Tray Sensor Assembly for OPT1 Tray, OPT2 Tray, or OPT3 Tray
of the LCIF.
Removal
1. Remove the LCIF Drive Assembly (DRP 7.15).
2. Place the LCIF Drive Assembly on a flat and stable work surface.
3. Disconnect the P/J leading from the Tray Sensor Assembly.
4. Squeeze together the four latches securing the Tray Sensor Assembly to the LCIF Drive Assembly and
remove the Tray Sensor Assembly.
Replacement
1. Position the Tray Sensor Assembly against the cutout in the LCIF Drive Assembly.
2. Push the Assembly into the cutout.
The latches snap into place.
3. Reconnect the P/J leading from the Tray Sensor Assembly.
4. Reinstall the LCIF Drive Assembly (DRP 7.15).