DRP 7.13 LCIF Motor (PL21.2.6)
Removal
1. Remove the LCIF Rear Cover (DRP 7.2).
2. Disconnect P/J 183 from the Motor PWB.
3. Remove the four screws securing the LCIF Motor to the Gear Assembly and remove the Motor.
Replacement
1. Reinstall the LCIF Motor onto the Gear Assembly by inserting the Motor drive shaft into the drive shaft hole
in the Gear Assembly.
2. Reposition the LCIF Motor so the four screw holes in the Motor PWB line up with the four screw holes in
the Gear Assembly.
3. Use four screws to secure the LCIF Motor to the Gear Assembly.
4. Reconnect P/J 183 to the Motor PWB.
5. Reinstall the LCIF Rear Cover (DRP 7.2).