DRP 7.18 Feed Roll Assembly (PL22.2.13)
Use this procedure to remove and replace the Feed Roll Assembly for OPT1 Tray, OPT2 Tray, or OPT3 Tray of
the LCIF.
Removal
1. Remove the LCIF Drive Assembly (DRP 7.15).
2. Place the LCIF Drive Assembly on a flat and stable work surface.
3. Remove the Feed Spring from the Feed Gear.
4. Remove the E ring securing the Feed Gear to the Feed Roll shaft and remove the Gear.
5. Remove the Idler Gear.
6. Remove the E ring securing the Feed Roll shaft to the rear bearing.
7. Slide the Feed Roll Assembly far enough to the rear of the Feeder Assembly so the front of the Feed Roll
Assembly clears the Guide.
8. Remove the Feed Roll Assembly from the Feeder Assembly.
Replacement
1. Slide the rear bearing, lip facing in, over the end of the Feed Roll Assembly shaft.
2. Insert the rear of the Feed Roll Assembly shaft into the cutout in the rear of the Drive Assembly.
3. Insert the front of the Feed Roll Assembly shaft into the Guide that is located at the front of the Drive
Assembly
4. Insert the rear bearing into the cutout and use an E ring to secure the Feed Roll shaft to the rear bearing.
5. Reinstall the Idler Gear onto the end of the Feed Roll Assembly shaft.
6. Push the Feed Solenoid arm out of the way as you reinstall the Feed Gear onto the end of the Feed Roll
shaft.
7. Use and E ring to secure the Feed Gear to the end of the Feed shaft.
8. Reattach the Feed Spring to the Feed Gear.
9. Reinstall the LCIF Drive Assembly (DRP 7.15).