MINOLTA-QMS magicolor 330 Service Manual page 69

Large-capacity input feeder
Table of Contents

Advertisement

DRP 7.9 LCIF Cover Assembly (PL21.1.30)
Removal
1. Remove the LCIF Right Cover (DRP 7.6).
2. Open the LCIF Cover.
3. Remove the two screws securing the ends of the two Cover Supports to the Cover and free the ends of the
Supports.
4. Push the Cover Assembly to the front of the LCIF frame so the rear pivot arm snaps free of the rear pivot
hole and remove the Cover from the frame.
Replacement
1. Install the front pivot arm of the LCIF Cover Assembly into the front pivot hole in the LCIF frame.
2. Install the rear pivot arm of the LCIF Cover Assembly into the rear pivot hole in the LCIF frame.
3. Reinstall the ends of the two Cover Supports onto the posts on the sides of the LCIF Cover.
4. Use two screws to secure the ends of the Cover Supports to the LCIF Cover.
5. Close the LCIF Cover.
magicolor 330 Large-Capacity Input Feeder Service Manual
LCIF-65