Large-capacity input feeder
Table of Contents

Advertisement

DRP 7.6 LCIF Left Cover (PL21.1.10)
Removal
1. Slide Trays 2, 3, and 4 a few inches out of the LCIF.
2. Remove the four screws securing the LCIF Left Cover to the LCIF frame
3. Slide the Left Cover to the front, to feed the rear latch, and remove the Cover.
Replacement
1. Slide Trays 2, 3, and 4 a few inches out of the LCIF.
2. Reinstall the LCIF Left Cover to the LCIF frame by sliding the rear latch into the tab at the rear of the LCIF.
3. Use four screws to secure the Cover to the frame.
4. Slide Trays 2, 3, and 4 back into the LCIF.