DRP 7.20 Feed Solenoid (PL22.2.21)
Use this procedure to remove and replace the Feed Solenoid for OPT1 Tray, OPT2 Tray, or OPT3 Tray of the
LCIF.
Removal
1. Remove the LCIF Motor Assembly (DRP 7.11).
2. Free the Feed Solenoid wire harness from the harness clip.
3. Remove the screw securing the Feed Solenoid to the LCIF frame.
4. Push down on the Feed Solenoid arm and remove the Solenoid from the LCIF frame.
Replacement
1. Position the Feed Solenoid as shown in the illustration.
2. Push down on the Feed Solenoid arm as you reinstall the Solenoid onto the LCIF frame.
3. Line up the three holes in the Solenoid with the screw hole and two positioning tabs on the frame.
4. Use one screw to secure the Feed Solenoid to the LCIF frame.
5. Secure the Feed Solenoid wire harness to the harness clip.
6. Reinstall the LCIF Motor Assembly (DRP 7.11).