MINOLTA-QMS magicolor 330 Service Manual page 89

Large-capacity input feeder
Table of Contents

Advertisement

DRP 7.19 Feed Roll (PL22.2.15)
We recommend that you replace Feed Rolls as a set.
Removal
1. Remove the Tray Sensor Assembly (DRP 7.22) but do not disconnect the Sensor P/J.
2. Reach in through the empty Paper Tray cavity and push the Feed Roll off of the Feed Roll shaft.
Replacement
1. Insert the Feed Roll pin into the large end of the Feed Roll hole and firmly press the Feed Roll onto the
shaft.
2. Reinstall the Tray Sensor Assembly (DRP 7.22).
magicolor 330 Large-Capacity Input Feeder Service Manual
If you have difficulty replacing the Feed Rolls as described in the following steps, we
suggest that you first remove the LCIF Drive Assembly (DRP 7.15) to make Feed Roll
removal and replacement easier.
LCIF-85