6.1.3.2 VTERM (DOS O/S)
1. Bootup Portable Computer to DOS
2. At the C:\ prompt, type "VTERM"
3. Once VTERM has started, enter the setup menu, select "F5"
4. Make the following the selections in the setup menus:
Terminal type; select "VT100 (ANSI)
Communications rate; select "9600"
Data bits/parity; select "8 NONE"
Stop bits; select "ONE"
Auto Xon/Xoff; select "ON"
5. The setup procedure is now completed, select "Esc" to end setup.
6. Power "ON" the printer (wait for the printer to finish it's power up sequence before proceding)
VTERM will automatically connect to the serial cable through the Com port.
7. Press the "Ctrl" & "D" keys simultaneously to reach the "<DBG> prompt
8. Type "edg" for the Main Menu to appear
You are now ready to run the Engine Diagnostics.
9.
LCIF-44
If a test result becomes suspect during the Engine Diagnostic testing, the printer should
be turned "OFF" and then steps 5 through 7 should be repeated. After the printer has
powered back up, repeat the suspect test to confirm the results of the initial test.