DRP 7.22 Low Paper Sensor (PL22.2.40)
Use this procedure to remove and replace the Low Paper Sensor for OPT1 Tray, OPT2 Tray, or OPT3 Tray of
the LCIF.
Removal
1. Remove the LCIF Drive Assembly (DRP 7.15).
2. Place the LCIF Drive Assembly on a flat and stable work surface.
3. Disconnect the P/J leading from the Low Paper Sensor.
4. Remove the screw securing the Low Paper Sensor to the Sensor Bracket and remove the Sensor.
Replacement
1. Reinstall the Low Paper Sensor onto the Sensor Bracket.
2. Line up the two holes in the Sensor with the screw hole and positioning tab on the Sensor Bracket.
3. Use one screw to secure the Low Paper Sensor to the Sensor Bracket.
4. Reconnect P/J leading form the Low Paper Sensor.
5. Reinstall the LCIF Drive Assembly (DRP 7.15).