9.5 Set Communication Control

In communication control interface, you can view the number of bytes per image in the
transmission stream, and set data packet size.
Steps:
1. Click Communication Control > Payload Size(B).
2. Check value in Payload Size(B).
3. Set GEV SCPS Packet Size(B) according to actual demands.
Figure 9-7 Set Communication Control

9.6 Update Firmware

9.6.1 Update Firmware via MVS

The device supports updating firmware via MVS client.
 Before updating, make sure power cable and others are properly connected.
 Please use the firmware package of the corresponding device model for updating.
Steps:
1. Click Tool > Firmware Updater to open the update interface.
2. Click
to select the device you want to update.
3. Click
to select the update file in the local computer.
4. Click Upgrade to start upgrading.