Chamber size
Electrical data (model versions VDL023-230V, VDL056-230V, VDL115-230V) (continued)
at 50 Hz power frequency
Nominal voltage
(+/-10%)
at 60 Hz power frequency
Current type
Nominal power
Nominal current
Chamber fuse 5 x 20 mm / 250V / time-lag T
Power plug
Over-voltage category acc. to IEC 61010-1
Pollution degree acc. to IEC 61010-1
Different electrical data for VD-UL constructed for the USA and Canada
(model versions VDL023UL-120V, VDL056UL-120V, VDL115UL-120V)
Nominal voltage (+/-10%) at 60 Hz power fre-
quency
Nominal current
Chamber fuse 5 x 20 mm / 250V / time-lag T
Chamber fuse 6.3 x 32 mm / 250V / time-lag T
Power plug
Environment-specific data
VDL noise level (mean value)
Energy consumption at 100 °C / 212 °F
*** Data not yet determined
All technical data is specified for unloaded chambers with standard equipment (with aluminum racks) at
an ambient temperature of +22 °C +/- 3 °C / 71.6 °F +/- 5.4 °F and a power supply voltage fluctuation of
+/- 10 %. Technical data is determined in accordance to BINDER Factory Standard Part 2:2015 and DIN
12880:2007.
All indications are average values, typical for chambers produced in series. We reserve the right
to change technical specifications at any time.
29.4

Equipment and options (extract)

To operate the VDL vacuum drying oven, use only original BINDER accessories or accessori-
es / components from third-party suppliers authorized by BINDER. The user is responsible for
any risk arising from using unauthorized accessories.
Regular equipment
Microprocessor display program controller MB2 with touch screen
Ethernet interface for computer communication
USB interface
Safety controller (safety device class 2 according to DIN 12880:2007)
Universal connection for inert gas / ambient air inlet „GAS/AIR", adapter with 8 mm hose olive, with fine-
dosing valve for inert gas / ambient air
Pressure regulator (rear) for sweeping with compressed air
Analog pressure display (manometer) for sweeping with compressed air
Pressure switch for heating release at 100 mbar
Measuring connection (DN 16), rear
2 vacuum expansion racks
Safety glass panel
VDL (E3) 09/2019
23
V
230
V
230
1N~
kW
0,90
A
3,9
A
2 x 6,3
Grounded plug
II
2
V
120
A
7,5
A
10
A
--
NEMA
5-15P
dB (A)
***
Wh/h
130
56
115
230
230
230
230
1N~
1N~
1,40
1,60
6,1
7,0
2 x 8
2 x 10
II
II
2
2
120
120
11,7
13,4
2 x 16
--
--
2 x 20
5-20P
5-20P
***
***
190
220