EC – Declaration of Conformity EG – KONFORMITÄTSERKLÄRUNG EC - DECLARATION OF CONFORMITY CE - DECLARATION DE CONFORMITE BINDER GmbH Anbieter / Supplier / Fournisseur: Im Mittleren Ösch 5, D-78532 Tuttlingen Anschrift / Address / Adresse: Vakuumtrockenschränke mit Programmregelung Produkt / Product / Produit: Vacuum drying ovens with program control Etuves de séchage à...
Page 3
Die oben beschriebenen Produkte sind konform mit folgenden harmonisierten Normen: The products described above are in conformity with the following harmonized standards: Les produits décrits ci-dessus sont conformes aux normes harmonisées suivantes: Sicherheit / safety / sécurité: EN 61010-1:2010 Sicherheitsbestimmungen für elektrische Mess-, Steuer-, Regel- und Laborgeräte –...
Page 4
D-78532 Tuttlingen, 03.08.2011 BINDER GmbH P. M. Binder Dr. H. von Both Geschäftsführender Gesellschafter Leiter F & E Managing Director Director R & D Directeur général Chef de service R&D 3 / 3 VD (E2.1) 10/2011 page 4/83...
Contents EC – Declaration of Conformity........................2 Product registration ............................5 SAFETY........................8 Legal considerations ...........................8 Structure of the safety instructions......................8 1.2.1 Signal word panel ........................8 1.2.2 Safety alert symbol ........................9 1.2.3 Pictograms ..........................9 1.2.4 Word message panel structure....................10 Localization / position of safety labels on the unit................10 Type plate ............................11 General safety instructions on installing and operating the vacuum drying oven ......12 Intended use .............................14...
Page 7
(option) ..........................63 16.7 Measuring access port vacuum 9 poles (option) ................64 16.8 Communication software APT-COM™ 3 DataControlSystem (option) ..........65 16.9 Protocol printer (available via BINDER INDIVIDUAL customized solutions)........65 17. MAINTENANCE, CLEANING, AND SERVICE ............ 66 17.1 Maintenance intervals, service......................66 17.2 Cleaning and decontamination ......................66...
Understanding and observing the instructions in this operating manual are prerequisites for hazard-free use and safety during operation and maintenance. In no event shall BINDER be held liable for any damages, direct or incidental arising out of or related to the use of this manual.
WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious (irreversible) injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in moderate or minor (reversible) injury. CAUTION Indicates a potentially hazardous situation, which, if not avoided, may result in damage to the product and/or its functions or to property in its proximity.
Pictograms (Warning signs) Service label Hot surface Figure 1: Position of labels on the unit Keep safety labels complete and legible. Replace safety labels that are no longer legible. Contact BINDER Service for these replacements. VD (E2.1) 10/2011 page 10/83...
Tel. + 49 (0) 7462/ 2005-0 Made in Germany Internet: www.binder-world.com Figure 3: Type plate (example of VD 23 regular unit) Indications of the type plate Information BINDER Manufacturer: BINDER GmbH VD 23 Model VD 23 Serial No. 00-00000 Serial No. 00-00000 Nominal temperature 200 °C...
(for Germany. BINDER GmbH is only responsible for the safety features of the unit provided skilled electricians or qualified personnel authorized by BINDER perform all maintenance and repair, and if components relating to chamber safety are replaced in the event of failure with original spare parts.
Page 13
DANGER Explosion hazard. Danger of death. ∅ Do NOT introduce any substance into the oven which is combustible or explosive at working temperature. ∅ NO explosive dust or air-solvent mixture in the inner chamber. ∅ Do NOT use the vacuum drying oven for drying or heat treatments leading to release of combustible vapors able to form an explosive mixture with air.
Intended use The VD vacuum drying ovens are suitable for drying and heat treatment of solid or pulverized charging material, as well as bulk material, using the supply of heat under vacuum. The solvent content must not be explosive or flammable. A mixture of any component of the charging material with air must NOT be explosive.
Overview of the equipment Figure 4: VD 23 with option vacuum module and chemical membrane pump Control panel Unit door Elastic-mounted safety glass window Vacuum module (option) Chemical membrane pump (option) VD (E2.1) 10/2011 page 15/83...
VD 23 control panel (2a) AIR/GAS VAC.OFF VAC.ON Figure 5: VD 23 control panel On/off switch (main power switch) Temperature safety device class 2 (2a) Red alarm lamp of the safety device class 2 Manometer (pressure reading) Aeration valve (inert gas or ambient air) Program controller RD3 Vacuum shut-off valve VD 53 / 115 control panel...
Connections at the rear of the unit (10) (11) (12) (13) (14) (15) (16) (9) (17) Figure 7: Rear of VD RS 422 serial interface for computer communication (10) Miniature fuse (11) Power connection line (12) Inert gas connection, adapter with hose olive ∅ 8 mm / 0.31 in (VD23: also simultaneous fresh air connection) (13) Vacuum connection with small flange DN16 (14) DIN socket (option) for option “object temperature display”...
Second-hand units are units that were used for a short time for tests or exhibitions. They are thoroughly tested before resale. BINDER ensures that the chamber is technically sound and will work flawlessly. Second-hand units are marked with a sticker on the unit door. Please remove the sticker before commissioning the unit.
Lift units size 115 with the aid of 6 people. • Permissible ambient temperature range during transport: -10 °C / 14°F to +60 °C / 140°F. You can order transport packing for moving or shipping purposes from BINDER Service. Storage Intermediate storage of the unit in a closed and dry room.
(see technical ventilation measures in the guideline BGI/GUV-I 850-0 on safe working in laboratories (formerly BGR/GUV-R 120 or ZH 1/119 laboratory guidelines issued by the employers’ liability insurance association) (for Germany). The maximum permissible ambient temperature of the vacuum pumps delivered by BINDER is 40 °C / 104°F. Installation and connections...
For connecting to the unit, BINDER recommends the connection kit VD, Art. no. 8012-0146. With the option “stainless steel tubing” between the vacuum oven and vacuum module, the vacuum connection is already located inside the vacuum module.
Inert gas connection When operating the VD vacuum drying oven with inert gas, correctly follow the technical ventilation measures, as described in the guideline BGI/GUV-I 850-0 on safe working in laboratories (formerly BGR/GUV-R 120 or ZH 1/119 laboratory guidelines issued by the employers’ liability insurance association) (for Germany).
Page 23
(setting in the user level, chap. 10). This setting is then valid for all program sections. Programming can be done directly through the keypad of the controller or graphically through the software APT-COM™ 3 DataControlSystem (option, chap. 16.8) specially developed by BINDER. VD (E2.1) 10/2011...
General indications The program controller RD3 offers several functional levels: Normal Display / Fixed value operation: • Display of the temperature actual value (display 1) and of the actual date and time (display 2). • The oven is in fixed value operating mode, equilibrating to the entered set-points. Fixed value entry mode (chap.
Fixed value entry mode If you do not want to use the week program timer, deactivate it (factory setting, setting in the user level, chap. 10) before entering any set-points. Any setting of the operation lines in fixed value entry mode is ineffective with active week program timer. Basic entry principle: Access the individual parameters with button X/W.
CAUTION Too high or too low temperature. Damage to the charging material. Deactivate the week program timer if you do not use it. Week program editor The Week program editor permits defining up to 4 shift point for each week day. A shift point defines a moment and the switching state ON or OFF of the channels that become active in this instance.
Page 27
Display 1 shows 0000 Display 2 shows Shiftpt. (no function) Press program key Display 1 shows 0000 Display 2 shows (selection of the shift point) Shiftpt. (actual shift point: 1) Select the shift point (1 up to 4) with key Value is shown in display 2.
Program table template for Week program Editor Program editor Program title Project Date: Day of the week Time Channel 1 Channel 2* (temperature) hh:mm ON = SP2 OFF = SP1 Monday Tuesday Wednesday Thursday Friday Saturday Sunday * Channel 2 is non-functional in the standard unit VD (E2.1) 10/2011 page 28/83...
Programming example of the Week program editor 7.2.1 Desired time function During the day (12 hours) the oven shall maintain a temperature of +80 °C / 176°F, and during the night (12 hours) it shall cool down / stop heating (set-point 30 °C / 86°F). This program shall automatically run during the whole year, i.e.
7.2.3 Proceeding in detail 1. Settings in the user level • Activating the week program timer • Checking and, if necessary, setting the real time clock Normal Display Display 1 shows e.g. 39.8 (actual temperature value) Display 2 shows (actual date and time, actual switching state of week e.g.
Page 31
Display 1 shows e.g. 2006 (Actual setting: 2006) Display 2 shows Year 2006 (Setting the year of the real time clock) Set year (2006 up to 2050) using arrow keys Setting is shown in display 2. Press key Display 1 shows e.g.
Page 32
Press key Display 1 shows 80.0 (actual temperature set-point 2) Display 2 shows SP2 TEMPERATURE (variable: temperature in °C) Enter temperature set-point 80 °C using Value is shown in display 1. arrow keys Press the EXIT button. The controller changes to Normal Display. 3.
Page 33
Display 1 shows 06.00 (time of the selected shift point) Display 2 shows (entry of time of the selected shift point) Time 06:00 (actual setting: 6.00, i.e. 6 a.m.) Enter the time 06:00 using arrow keys Value is shown in display 2. Press key Display 1 shows 0000...
Page 34
Display 1 shows 0000 Display 2 shows (selection of day of the week) Tuesday (actual selection: Tuesday) Day of the week is shown in display 2. Select the next day of the week (Tuesday) with key Press program key Display 1 shows 0000 Display 2 shows Shiftpt.
Program editor Selecting between set-point ramp and set-point step You can program various kinds of temperature transitions. In the user level (chap. 10) you can select between the settings “Ramp” (default setting) and “Step”. Setting “Ramp” permits programming all kinds of temperature transitions. With setting “Step”...
Page 36
Program entry as set-point ramp (example): W/°C t/min. Program table corresponding to the diagram (with default setting “Ramp”): Section Temperature Section length Operation lines set-point [hh.mm] [ °C] TEMP O.LINE TIME 00:30 01:30 01:00 03:20 00:01 You can now enter the values of such a program table to the RD3 program controller (chap. 8.2). Program entry as set-point step (example): S01 S02 W/°C...
Program table corresponding to the diagram (with default setting “Ramp”): Section Temperature Section length Operation lines set-point [hh.mm] [ °C] TEMP TIME O.LINE 00:30 00:01 01:30 00:01 01:00 00:01 03:20 00:01 You can now enter the values of such a program table to the RD3 program controller (chap. 8.2). Program the end point of the desired cycle with an additional section (in our examples S05 for set-point ramp and S08 for set-point step) with a section time of at least one minute.
Program table corresponding to the diagram (with setting “Step”): Section Temperature Section length Operation lines set-point [hh.mm] [ °C] TEMP TIME O.LINE 00:30 01:30 01:00 03:20 You can now enter the values of such a program table to the RD3 program controller (chap. 8.2). 8.1.3 General notes on programming temperature transitions When exceeding the tolerance limits set in the user level (chap.
Page 39
Step 1 – Selecting the program and the first program section to be entered: Normal Display Display 1 shows e.g. 39.8 (actual temperature value) Display 2 shows (actual date and time, actual switching state of week e.g. 15.05.06 13:52 - - program timer channel 1: Off, channel 2: Off) Press down key for 5 sec.
Page 40
Next step – set-point entry in the desired program sections: Basic entry principle: Access the parameters of individual program sections with button X/W one after the other. Enter the values of the individual parameters with the arrow keys. A value flashing once after 2 seconds indicates that it has been adopted by the controller.
Program table template Program editor Program title Project Program No. Date: Section Temperature set-point Section length Operation lines * [ °C] [hh.mm] O.LINE TEMP TIME * Switching contacts 24V DC via operation lines, see chap. 15. VD (E2.1) 10/2011 page 41/83...
Deleting a program section A program section is deleted from the program by setting the section duration to Zero. Normal display Press down key for 5 sec. Display 1 shows e.g. 0000 Display 2 shows PROGRAM EDITOR (you are in the program editor) Press program key Display 1 shows 0000...
The following section (in our example now S03) is displayed: Display 1 shows e.g. 03 (actual selection of the section: S03) Display 2 shows P01:S03 (program section can be selected) alternating CONTINUE X/W (information: set-point entry with X/W) Press key EXIT or wait 120 sec Controller returns to Normal Display If you delete a program section which is followed by further sections, those following move up...
Page 44
Deactivate the week program timer (factory setting, setting in the user level, chap. 10) before starting a program. Step 1 – Program selection (only with program type “2 programs” set) Normal Display Press program key Display 1 shows e.g. 1 (actual selection of the program) Display 2 shows SEL.PRG.
Page 45
If you press button during program course, the entered set-point of the actually running program section is shown for 5 sec: Display 1 shows e.g. 65.5 (actual temperature value) Display 2 shows (actual program P01, actual section S03, and remaining time P01:S03 00:47:12 of program section S03) Press key...
User level In this menu you can set the following parameters (in brackets the corresponding abbreviated information given in display 2): • Unit address (Adress) Setting of controller address (1 to 255) for operation with the communication software APT-COM™. • User code (User-cod) Modification of the user code setting (factory setting 0001) for access to the user level and the program editor.
Page 47
• Program type selection (PrgSelec) Select between entry of two programs with up to 10 sections each or of one program with up to 20 sections. When changing from 2 programs to 1 program or vice-versa, existing programs are deleted in the program editor! •...
Page 48
• Month of the real time clock (Month) Enter the month (1 up to 12). • Day of the real time clock (Day) Enter the day (1 up to 31). • Time of the real time clock (Time) Main menu. Use the program key to access the settings of hour and minute in the corresponding submenus.
Page 49
Display 1 shows (actually valid user code: 1) Display 2 shows (change user code) User-cod (actually set: 1) Enter a new value using arrow keys Value is shown in both displays. Press key Display 1 shows 0000 (no function) Display 2 shows Saf.mode: Limit (no function)
Page 50
Press key Display 1 shows 0000 (no function) Display 2 shows (Selection of interface mode) Protocol: MODBUS (actual setting: Modbus) Select between protocols “MODBUS” and Setting is shown in display 2. “Printer” using arrow keys Press key Display 1 shows e.g.
Page 51
Select between “Active” and “Inactive” using Setting is shown in display 2. arrow keys Press key Display 1 shows 0000 Display 2 shows (Display mode 12 hours or 24 hours? 12h/24h (actual setting: 24h) Select between 12 hours and 24 hours Setting is shown in display 2.
Performance in case of failures 11.1 Performance after power failure Power failure during fixed-value operation (Normal Display): The entered parameters remain saved. After power returns operation continues with the set parameters. Power failure during program operation: After the power returns, program course continues with the set-points that have been reached previously during program operation.
If the safety device has turned off the oven, identifiable by the red alarm lamp (2a) lighting up, proceed as follows: • Disconnect the oven from the power supply • Have an expert examine and rectify the cause of the fault •...
If you note an excessive divergence between the controller and reference temperatures, please contact BINDER Service to calibrate the temperature controller. Commissioning the vacuum With regard to operation, please observe the guideline BGI/GUV-I 850-0 on safe working in laboratories (formerly BGR/GUV-R 120 or ZH 1/119 laboratory guidelines issued by the employers’...
14.2 Breaking the vacuum (flooding) When the drying procedure is complete, the vacuum in the inner container is broken (flooded). • VD 23: open air/gas valve (4) • VD 53 and VD 115: open aeration valve (5) and fine dosing valve for inert gas (6) Fresh air is introduced into the lower part of the rear panel of the inner chamber and is evenly distributed in the inner chamber.
Page 56
• Operation line 1: Program controlled evacuation (option “vacuum module with pump”, see chap. 16.3) • Operation line 2: Program controlled venting (option “program controlled venting”, available via BINDER INDIVIDUAL customized solutions) You can connect any other device or electrical equipment with a nominal tension of 24 V DC and a current consumption of max.
Options 16.1 Connection kit VD (option) The VD connection kit VD (Art. no. 8012-0146) consists of: • Aluminum straining ring DN10/16 • Outer centering ring DN10/16 • Small flange with hose tulles DN16/8 • 2.5 m / 98.4 in caoutchouc hose 6/12 mm •...
Page 58
When using a vacuum hose, we recommend using the BINDER connection kit VD Art. no. 8012-0146 (chap. 16.1. The module has an appropriate hose outlet at the back.
16.3 Vacuum module with chemical membrane pump VP 1.1 or VP 2.1 (option) The mounting instructions Art. no. 7001-0137 supplied with the vacuum module describe how to mount the VD vacuum drying oven onto the vacuum module and installing the suction line into the vacuum module.
Page 60
Maximum admissible load of the socket: Standard 230 V / 50 Hz - 16 Amp CUL-version 120 V / 60 Hz - 13 Amp With CUL-version, connect only a UL listed vacuum pump with ratings of 120 V AC, 60 Hz, and less or equal 12 Amp, 0.5 HP.
Observe the permitted gas temperature. The following values refer to the maximum ambient temperature of the pump of 40 °C / 104°F. Operation condition Inlet pressure Permitted gas temperature Continuous operation > 100 mbar / 2.95 inHg (high gas load) +10 °C to +40 °C / 50°F to 104°F Continuous operation <...
Page 62
Programming of descendant pressure cycles as well as documentation of pressure data are possible via the RS 232 serial interface of the vacuum controller CVC 3000 by use of the BINDER communication software APT-COM™ DataControlSystem (option, chap. 16.8).
The object temperature data is put out combined with the temperature data of the temperature controller to the RS 422 interface as a second measuring channel. This permits recording by the BINDER documentation software APT-COM™ DataControlSystem (option, chap. 16.8).
Figure 25: Measuring connection (17) with Figure 26: Pt100 connection (14) at the rear of the unit measuring access port Technical data of the Pt 100 sensor: • Three-wire technique • Class B (DIN EN 60751) • Temperature range up to 300 °C / 572°F •...
16.8 Communication software APT-COM™ 3 DataControlSystem (option) The unit is regularly equipped with a serial interface RS 422 (9) that can connect the BINDER communication software APT-COM™ 3 DataControlSystem. The actual temperature value is given at adjustable intervals. Programming can be performed graphically via PC. Up to 30 chambers with RS 422 interface can be cross-linked.
The warranty becomes void if maintenance work is conducted by non-authorized personnel. Replace the door gasket only when cold. Otherwise, the door gasket may become damaged. We recommend taking out a maintenance agreement. Please consult BINDER Service. BINDER telephone hotline:...
17.3 Sending the unit back to BINDER GmbH If you return a BINDER product to us for repair or any other reason, we will only accept the product upon presentation of an authorization number that has previously been issued to you. An authorization number will be issued after receiving your complaint either in writing or by telephone prior to your sending the BINDER product back to us.
The authorization number must be applied to the packaging in such a way that it can be easily recognized or be recorded clearly in the delivery documents. For security reasons we cannot accept a unit delivery if it does not carry an authorization number.
(Elektro- und Elektronikgerätegesetz, ElektroG) from 23 March 2005, BGBl. I p. 762 or contact BINDER Service who will organize taking back and disposal of the unit according to the German national law for electrical and electronic equipment (Elektro- und Elektronikgerätegesetz, ElektroG) from 23 March 2005,...
According to directive 2002/96/EC of the European Parliament and of the Council on waste electrical and electronic equipment (WEEE), BINDER devices are classified as “monitoring and control instruments” (category 9) only intended for professional use“. They must not be disposed of at public collecting points.
Alteration of the environment. For final decommissioning and disposal of the vacuum drying oven, please contact BINDER Service. Follow the statutory regulations for appropriate, environmentally friendly disposal. The main board of the vacuum drying oven includes a lithium cell. Please dispose of it according to national regulations.
Check temperature set- point and setting of safety device (chap. 12). If appropriate, select suitable limit value. Safety device defective. Contact BINDER Service. Controller defective. Heating Set-point temperature is not Unit door not properly closed. Completely close unit door.
(certified since December 1996 by TÜV CERT). All test equipment used is subject to the administration of measurement and test equipment that is also a constituent part of the BINDER QM DIN EN ISO 9001 systems. They are controlled and calibrated to a DKD-Standard at regular intervals.
77°F and a power supply voltage fluctuation of ±10. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10% of the height, width and depth of the inner chamber.
Page 76
Communication software APT-COM™ for logging and display of temperature data and networking up to 30 units with PC Protocol printer for numeric and graphic temperature documentation (BINDER Individual) 2-channel pen recorder, external (BINDER Individual) Connection kit VD with various small flange parts...
20.4 Spare parts BINDER GmbH is responsible for the safety features of the unit only, provided skilled electricians or qualified personnel authorized by BINDER perform all maintenance and repair, and if components relating to chamber safety are replaced in the event of failure with original spare parts.
Contamination clearance certificate Unbedenklichkeitsbescheinigung Declaration regarding safety and health Erklärung zur Sicherheit and gesundheitlichen Unbedenklichkeit The German Ordinance on Hazardous Substances (GefStofV), and the regulations regarding safety at the workplace, require that this form be filled out for all products that are returned to us, so that the safety and the health of our employees can be guaranteed.
Page 82
Kind of transport / transporter / Transport by (means and name of transport company, etc.) Versendung durch (Name Spediteur o.ä.) __________________________________________________________________________________ Date of dispatch to BINDER GmbH / Tag der Absendung an BINDER GmbH __________________________________________________________________________________ VD (E2.1) 10/2011 page 82/83...
Page 83
We are aware that, in accordance with Article 823 of the German Civil Code (BGB), we are directly liable with regard to third parties, in this instance especially the employees of BINDER GmbH, who have been entrusted with the handling / repair of the unit / component. / Es ist uns bekannt, dass wir gegenüber Dritten –...