F425

Forward Speed Limit Input

Program ⇒ Torque Setting Parameters ⇒ Torque Speed Limiting
This parameter Enables/Disables the Forward Speed Limit Input control
function. When enabled and operating in the Torque Control mode, the
forward speed limit is controlled by the terminal selected here. If Setting is
selected, the value set at
F426
Settings:
Disabled
VI/II
RR
RX
RX2 (option)
Setting
Forward Speed Limit Level
Program ⇒ Torque Setting Parameters ⇒ Torque Control
This parameter provides a value to be used as the Forward Speed Limit setting
if Setting is selected at F425.
Reverse Speed Limit Input
Program ⇒ Torque Setting Parameters ⇒ Torque Control
This parameter Enables/Disables the Reverse Speed Limit Input control
function. When enabled and operating in the Torque Control mode, the reverse
speed limit is controlled by the terminal selected here. If Setting is selected, the
value set at
F428
is used as the Reverse Speed Limit input.
Settings:
Disabled
VI/II
RR
RX
RX2 (option)
Setting
Reverse Speed Limit Level
Program ⇒ Torque Setting Parameters ⇒ Torque Control
This parameter provides a value to be used as the Reverse Speed Limit setting
if Setting is selected at F427.
G7 ASD Operation Manual
is used as the Forward Speed Limit input.
Direct Access Number — F425
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — Yes
Direct Access Number — F426
Parameter Type — Numerical
Factory Default — 80.0
Changeable During Run — Yes
Minimum — 0.00
Maximum — Upper Limit (F012)
Units — Hz
Direct Access Number — F427
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — Yes
Direct Access Number — F428
Parameter Type — Numerical
Factory Default — 80.0
Changeable During Run — Yes
Minimum — 0.00
Maximum — Upper Limit (F012)
Units — Hz