F654
Torque Boost Adjustment
Program ⇒ Terminal Selection Parameters ⇒ Analog Input Functions
This parameter Enables/Disables the feature that allows for the external
adjustment of the Torque Boost setting. Selecting either VI/II or RR enables
this feature. The selected input is used as a modifier of the programmed Torque
Boost setting.
Settings:
Disabled
VI/II
RR
Frequency Override Additive Input
Program ⇒ Feedback Parameters ⇒ Override Control
This parameter Enables/Disables the feature that allows for the external
adjustment of the Output Frequency.
Selecting either of the input methods listed enables this feature. The selected
input is used as a modifier of the programmed Output Frequency.
Settings:
Disabled
VI/II
RR
RX
RX2 (option)
LED Keypad (option)
Binary/BCD Input
Common Serial (TTL)
RS232/RS485
Communication Card
Motorized Pot
Pulse Input 1
Frequency Override Multiplying Input
Program ⇒ Feedback Parameters ⇒ Override Control
This parameter Enables/Disables the feature that allows for the external
adjustment of the Output Frequency.
Selecting either of the input methods listed enables this feature. The selected
input is used as a multiplier of the programmed Output Frequency.
If operating using the LED Keypad Option and Setting is selected, the value
entered at
F729
is used as the multiplier.
Settings:
Disabled
VI/II
RR
RX
RX2 (option)
Setting (LED Keypad Option Only)
162
Direct Access Number — F654
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — Yes
Direct Access Number — F660
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — No
Direct Access Number — F661
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — No