F530

Group #1 Speed Repeat Factor

Program ⇒ Pattern Run Control Parameters ⇒ Speeds
This parameter sets the number of times that the pattern defined in Group #1
will be run.
Group #1 Speed #1 (Pattern Run)
Program ⇒ Pattern Run Control Parameters ⇒ Speeds
Up to four groups of Preset Speeds may be setup and run from this screen. The
Preset Speed numbers (1 – 15) may be entered into the Speed # field to be run
for the number of times entered into the Repeat field (0 – 254) or forever by
selecting Infinite. Running multiple Preset Speeds as a group is called a
Pattern Run.
This parameter allows the user to run the Preset Speeds 1 – 15 as a group and
is identified as Group #1.
Skip may be selected to ignore a Preset Speed entry.
See
F520
for further information on this setting.
Group #1 Speed #2
Program ⇒ Pattern Run Control Parameters ⇒ Speeds
Same as #1 Group Speed #1 (see F531).
Group #1 Speed #3
Program ⇒ Pattern Run Control Parameters ⇒ Speeds
Same as #1 Group Speed #1 (see F531).
Group #1 Speed #4
Program ⇒ Pattern Run Control Parameters ⇒ Speeds
Same as #1 Group Speed #1 (see F531).
Group #1 Speed #5
Program ⇒ Pattern Run Control Parameters ⇒ Speeds
Same as #1 Group Speed #1 (see F531).
Group #1 Speed #6
Program ⇒ Pattern Run Control Parameters ⇒ Speeds
Same as #1 Group Speed #1 (see F531).
Group #1 Speed #7
Program ⇒ Pattern Run Control Parameters ⇒ Speeds
Same as #1 Group Speed #1 (see F531).
146
Direct Access Number — F530
Parameter Type — Numerical
Factory Default — 1
Changeable During Run — No
Minimum — 1
Maximum — Infinite
Direct Access Number — F531
Parameter Type — Selection List
Factory Default — 1
Changeable During Run — No
Direct Access Number — F532
Parameter Type — Selection List
Factory Default — 2
Changeable During Run — No
Direct Access Number — F533
Parameter Type — Selection List
Factory Default — 3
Changeable During Run — No
Direct Access Number — F534
Parameter Type — Selection List
Factory Default — 4
Changeable During Run — No
Direct Access Number — F535
Parameter Type — Selection List
Factory Default — 5
Changeable During Run — No
Direct Access Number — F536
Parameter Type — Selection List
Factory Default — 6
Changeable During Run — No
Direct Access Number — F537
Parameter Type — Selection List
Factory Default — 7
Changeable During Run — No
G7 ASD Operation Manual