F412

Motor Capacity

Program ⇒ Motor Parameters ⇒ Motor Settings
This parameter identifies the wattage rating of the motor.
Motor Type
Program ⇒ Motor Parameters ⇒ Motor Settings
This parameter identifies the type of motor being used.
Settings:
Toshiba EQP III TEFC
Toshiba EQP III ODP
Toshiba EPACT TEFC
Toshiba EPACT ODP
Other Motor

Motor Constant 3 Enable

Program ⇒ Motor Parameters ⇒ Vector Motor Model
This parameter Enables/Disables tuning of Motor Constant 3 during an
Autotune.
Settings:
Disabled
Enabled (box checked)

Torque Command

Program ⇒ Torque Setting Parameters ⇒ Torque Control
When operating in the Torque Control mode, this parameter allows the user to
select the source of the torque command signal.
Settings:
VI/II
RR
RX
RX2 (option)
LED Keypad Option
Binary/BCD Input
Common Serial (TTL)
RS232/RS485
Communication Card
Torque Command Filter
Program ⇒ Torque Setting Parameters ⇒ Torque Control
This parameter reduces the motor vibration caused by large-inertia loads. A
small value will have a great effect while an increased value will have a lesser
effect.
G7 ASD Operation Manual
Direct Access Number — F412
Parameter Type — Numerical
Factory Default — (ASD-dependent)
Changeable During Run — No
Minimum — 0.10
Maximum — (ASD-dependent)
Units — kW
Direct Access Number — F413
Parameter Type — Selection List
Factory Default — Toshiba EQP III
TEFC
Changeable During Run — No
Direct Access Number — F414
Parameter Type — Check Box
Factory Default — Enable
Changeable During Run — No
Direct Access Number — F420
Parameter Type — Selection List
Factory Default — RX
Changeable During Run — Yes
Direct Access Number — F421
Parameter Type — Numerical
Factory Default — 200.0
Changeable During Run — Yes
Minimum — 10.0
Maximum — 200.0
F421
129

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents