Removing the Downstream PHY Module in the Interface Line Card
Required Tools and Equipment
• ESD-preventive wrist strap
• T10 Torx-blade screwdriver
• Replacement line card or line card blank
• Antistatic Bag or mat
Step 1
Loosen the retaining screws (two in the front and one in the rear) using a T10 Torx-blade torque driver.
Step 2
Grasp the Downstream PHY module by its sides.
Step 3
Lift the Downstream PHY module off the cLGA connector guide pins and the rear guide pins on the line card.
Figure 151: Lift the Downstream PHY module
1
2
Ensure that the Downstream PHY module is held horizontal when it is lifted off the guide pins, to prevent
Note
damage to the cLGA connector surface.
Step 4
Place the removed Downstream PHY module in an antistatic bag.
What to do next
Replace the Downstream PHY