Huawei UA5000 Manual page 58

Environment monitoring
Hide thumbs Also See for UA5000:
Table of Contents

Advertisement

UA5000 Universal Access Unit
Environment Monitoring
Mapping Between Monitoring Parameters and Device Ports
Table 5-7
the ports on the ESCM.
Table 5-7 Mapping between the monitoring parameters displayed on the host and the ports on
the ESCM
Monitoring
Parameter
Displayed on the
Host
Temperature
Input_-48V_0
Analog 3
Analog 4
Wiring
Door0
Digital 2
Digital 3
Digital 4
Digital 5
Digital 6
Digital 7
Digital 8
Digital 9
Issue 01 (2012-08-17)
describes the mapping between the monitoring parameters displayed on the host and
Device Port
Temperature
Voltage
JTA1
JTA2
JTP1 (MDF)
JTM1 (door status)
JTD1
JTD2
JTD3
JTD4
JTD5
JTD6
JTD7
JTS1 (water)
NOTE
Before adding a user-defined analog or monitoring digital parameter, make sure that the port corresponding
to this analog or monitoring digital parameter is properly connected with an environment monitoring cable.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5 ESCM Monitoring Solution
Application in the M200 Cabinet
Temperature
Voltage
Humidity
Not connected by default, used to add a user-
defined monitoring analog parameter
MDF
Door status sensor
Not connected by default, used to add a user-
defined monitoring digital parameter
Not connected by default, used to add a user-
defined monitoring digital parameter
Not connected by default, used to add a user-
defined monitoring digital parameter
Not connected by default, used to add a user-
defined monitoring digital parameter
Not connected by default, used to add a user-
defined monitoring digital parameter
Not connected by default, used to add a user-
defined monitoring digital parameter
Not connected by default, used to add a user-
defined monitoring digital parameter
Not connected by default, used to add a user-
defined monitoring digital parameter