UA5000 Universal Access Unit
Environment Monitoring
15. Query the alarms, and confirm that the door status alarm other than alarms for other
Issue 01 (2012-08-17)
battery temperature alarm upper:
load off permit
battery off permit : permit
AC over alarm voltage
DC over alarm voltage
power module number: 2
module 0 address: 1
module 1 address: 2
Load high-temperature-off permit: forbid
Load high-temperature-off temperature(C): 70
Battery high-temperature-off permit: permit
Battery high-temperature-off temperature(C): 53
----------------------------------------------------------------------------
huawei(config-if-power4875l-0)#display power environment parameter
EMU ID: 2
parameter
----------------------------------------------------------------------------
AnalogID Name
Type
0
Temperature
Current
1
Humidity
Current
----------------------------------------------------------------------------
DigitalID Name
Level
0
Fan
0
2
-
1
4
Smoke
0
6
MDF-door
0
----------------------------------------------------------------------------
monitoring parameters is generated.
huawei(config-if-power4875l-0)#display power alarm
EMU ID: 0
----------------------------------------------------------------------------
Mains supply yes : Yes
Total Vol lack
: Normal
Load fuse 0
: Connect
Load off
: On
Battery 0 loop
: Disconnect
Environment Temperature : Normal
Door alarm
: Alarm
Fog alarm
: Normal
Module 0
: Normal
Module 1
: Normal
Module 2
: Normal
Battery temperature off state : Normal
----------------------------------------------------------------------------
Name
Spare Dig0(Fan)
Normal
Spare Dig2
Normal
Spare Dig4(Smoke)
Spare Dig6(MDF-door)
----------------------------------------------------------------------------
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
50C
battery temperature alarm lower: 0C
: forbid
load off voltage
battery off voltage : 43.000V
: 280V
AC lack alarm voltage : 180V
: 58 V
DC lack alarm voltage : 45V
module 0 switch state
module 1 switch state
Power environment configration
AlmUpper AlmLower TestUpper TestLower Unit
68
-5
80
10
Level
|DigitalID Name
0
|
0
|
1
|
Power alarm information
Mains supply lack : Normal
Second fuse
Battery off
Water alarm
Wiring alarm
State |Name
Normal|Spare(HABF_FAN)
Normal|Spare Dig3(SPD)
Normal|Spare Dig5(HEX)
Alarm
7 EPS75-4815AF Monitoring Solution
: 44.000V
: On
: On
80
-20
100
0
1
HABF_FAN
3
SPD
5
HEX
: Connect
: On
Environment Humidity
: Normal
: Normal
Load temperature off state : Normal
C
%R.H.
: Normal
State
Alarm