Maintenance and Service Guide (Model 2280)
NVMe SSD Adapter Signal Cabling
Figure 3-17 NVMe SSD adapter signal cabling
Table 3-17 NVMe SSD adapter signal cabling
No.
1
2
3
Issue 04 (2020-01-16)
Connectors and Cable
Slimline cable for connecting PORT 1A/PORT 1B/
PORT 1C (J17/J18/J19) of the front drive backplane
to NVMe SSD adapter 1
Slimline cable for connecting PORT 2C (J31) of the
front drive backplane to PORT C of NVMe SSD
adapter 2
Slimline cable for connecting PORT 2A/PORT 2B
(J21/J32) of the front drive backplane to NVMe SSD
adapter 2
● Connect cables according to port labels on cables and silkscreens on the NVMe SSD
adapters and drive backplane. For example, connect the cable labeled PORT A to PORT
A of the NVMe SSD adapter and PORT A of the drive backplane.
● When connecting cables, connect Slimline cables to PORT 2A, PORT 2B, and PORT 2C,
and then connect Slimline cables to PORT 1A, PORT 1B, and PORT 1C.
● When connecting Slimline cables, connect the shorter cables, and then connect the
longer ones.
● To facilitate operations, remove the backplane before removing the power cables.