Nvme Ssd Indicators; Drive Backplane Connectors - Huawei TaiShan 200 2280 Maintenance And Service Manual

Hide thumbs Also See for TaiShan 200 2280:
Table of Contents

Advertisement

TaiShan 200 Server
Maintenance and Service Guide (Model 2280)

2.6.3 NVMe SSD Indicators

Figure 2-20
Figure 2-20 NVMe SSD indicators
Table 2-11 NVMe SSD indicators
Drive Activity
Indicator
(Green
Indicator)
Off
Steady green
Blinking green
(2 Hz)
Off
Off
Steady green or
off

2.7 Drive Backplane Connectors

Issue 04 (2020-01-16)
shows the NVMe SSD indicators.
Drive Fault
Indicator
(Yellow
Indicator)
Off
Off
Off
Blinking yellow
(2 Hz)
Blinking yellow
at 0.5 Hz
Steady yellow
Figure 2-21
shows connectors on the backplane for 12 x 3.5-inch drives in
pass-through mode.
Copyright © Huawei Technologies Co., Ltd.
State Description
The NVMe SSD cannot be detected.
The NVMe SSD is detected and working
properly.
Data is being read from or written to the
NVMe SSD.
The NVMe SSD is being located or hot-
swapped.
The NVMe SSD completes the hot removal
process and is removable.
The NVMe SSD is faulty.