Delete or un-assign all server profiles.
Delete all logical enclosures.
Delete any storage volumes allocated within HPE OneView.
Reset managed devices (configured through IP address pools) to default IP addressing
2. From the main menu, select Settings, and then click Appliance.
3. Select Actions > Factory Reset.
4. Optionally select Preserve appliance network settings to erase the appliance data without losing network
connectivity, for example, to rebuild the appliance.
5. Select OK.
6. Select the appropriate option:
Reset to factory defaults while preserving appliance module network settings—Use this option to erase the
appliance module data without losing network connectivity, for example, for rebuilding the appliance module.
Full appliance factory reset to defaults—Use this option to prepare a system when returning or discarding
appliance module hardware, or when completely reusing a new appliance module with new communication
settings.
IMPORTANT: This option can cause you to lose your network connection to the appliance module.
Therefore, you must access the appliance module using its IPv6 link local address.
This action displays a progress bar while it is running. Logins are disabled automatically. When the appliance reset
is completed after several minutes, you can log in and set up your appliance module as you did for the first time.
7. If you are decommissioning the appliance, ensure that all hardware managed by HPE OneView is removed from
management.
This action displays a progress bar while it is running. Logins are disabled automatically. When the appliance module reset
is completed after several minutes, you can log in and set up your appliance module as you did for the first time.

Frame link module factory reset

IMPORTANT: When a frame is configured and is actively managed by HPE OneView, a factory reset should only be
performed when required by a recommended HPE OneView management or service process.
The Factory Reset action resets all frame link modules in a frame to factory default settings. Resetting a frame link module
to factory default settings will take the frame link module offline for up to 10 minutes. If the frame link module is installed
in a frame managed by HPE OneView, the frame link module will be reclaimed by HPE OneView after the factory reset is
complete.
Some instances where a factory reset may be necessary include:
Prior to moving a frame to a new HPE OneView environment.
After performing a factory reset of the HPE Synergy Composer that manages the frame.
For more information, see the HPE OneView for Synergy User Guide on the Hewlett Packard Enterprise Information
Library (http://www.hpe.com/info/synergy-docs).
110
Troubleshooting

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents