CAUTION:
•
This action erases appliance data including logs.
This action erases appliance data including logs and managed device settings in HPE OneView.
This action does not affect the configuration of managed devices in any way. Therefore, manual clean-up of
devices might be required if HPE OneView will no longer manage them.
•
REST API calls and GUI operations are not allowed during the reset action.
•
The Preserve network settings option does not change the cryptography mode. Verify that the cryptography
mode is set to the desired mode from Settings > Security, and review the Cryptography settings.
•
If the HPE Synergy Console does not return to a normal state with factory setting, it might be necessary to
reimage the appliance.
NOTE:
•
In an appliance cluster, the standby appliance module must be removed from the cluster before resetting the active
appliance. Removing the standby appliance module resets it to factory settings and shuts it down.
•
If you intend to restore the Composer settings from a backup file after it the Composer is reset or reimaged, and that
backup file contains the management configuration for the enclosures, you do not need to reset all managed frames to
their factory settings.
•
If you intend to re-import and manage the Synergy frames, you must perform these actions:
1. Reset the HPE OneView appliance to its factory settings.
2. Then, reset each frame managed by that Composer to their factory settings.
Resetting an HPE Synergy frame to factory defaults also removes the networking configuration on the
interconnects in those frames, which disrupts workloads running on compute modules in those frames.
•
If you do not have a backup file for HPE OneView, you will need to perform a factory reset on all the devices in the
domain.
Prerequisites
•
Minimum required privileges: Infrastructure administrator
•
Ensure that all tasks have been completed or stopped, and that all other users are logged off.
•
When resetting or reimaging a Composer to a factory-fresh state, you must also reset each frame managed by that
Composer to their factory-fresh state. However, if you intend to restore the Composer settings from a backup after it
is reset or reimaged, you do not need to reset each frame.
IMPORTANT: To reset the whole system to a factory-fresh state, you must also perform a factory reset on each
frame in the domain.
If you intend to restore the system from a backup file, you do not need to perform a factory reset of each frame.
Restoring the system from the backup file restores each frame to management.
•
Ensure that all tasks have been completed or stopped, and that all other users are logged off.
Procedure
1. If you are decommissioning the appliance and its managed environment, remove all hardware from HPE OneView
management, for example:
Troubleshooting
109