Item
Options
Baud Rate
115200*
57600
38400
19200
9600
4800
2400
1200
Data Bits
7 Bits
8 Bits*
Parity
None*
Even
Odd
Stop Bits
1 Bit*
2 Bits
Flow Control
None*
RTS/CTS
XON/XOFF
Information Wait Time
0 Second
2 Second
5 Second*
10 Second
30 Second
C.R. After Post
Yes*
No
Meaning
This item allows you to set the baud rate.
This item is only visible when Console Serial Redirect is set to Enabled.
This item allows you to set the number of data bits per character that are sent or received by the COM port.
This item is only visible when Console Serial Redirect is set to Enabled.
This item allows you to set whether character data is sent or received with a parity bit and how the parity bit
is set. The parity bit is an extra data bit (o or 1) that is added to each character for error-checking purposes.
This item is only visible when Console Serial Redirect is set to Enabled.
This item allows you to set the number of extra data bit(s) (1 or 2) that are added to each character to indicate
the end of the character.
This item is only visible when Console Serial Redirect is set to Enabled.
This item allows you to set the signal to use to pause and resume the transmission of data.
This item is only visible when Console Serial Redirect is set to Enabled.
By selecting None, no flow control is performed.
By selecting RTS/CTS, the serial port will send a request to send (RTS) signal. If the line is clear, the
connected device sends a clear to send (CTS) signal. Once received, your unit will begin transmitting data.
By selecting XON/XOFF, the connected device will send a transmitter-on (XON) signal. As its buffers get full, it
will send a transmitter-off (XOFF) signal to your unit and your unit will stop transmitting. When it is ready to
receive again, the connected device will send a transmitter-on (XON) signal.
This item allows you to set the number of seconds to display the initial console redirection screen. The
greater the specified time, the greater the amount of time that you have to launch your terminal emulation
program and receive the console redirect.
This item is only visible when Console Serial Redirect is set to Enabled.
This item allows you to specify whether console redirect is available after the POST or not.
This item is only visible when Console Serial Redirect is set to Enabled.