Starter Disassembly (Centrifugal Bendix) - Mercury 150 EFI Service Manual

Electronic fuel injection,
Table of Contents

Advertisement

CHARGING & STARTING SYSTEM

Starter Disassembly (Centrifugal Bendix)

1. Remove starter as outlined in Starter Removal.
2. Remove 2 through bolts from starter.
a -
b -
3. Tap commutator end cap to loosen and remove from frame. Do not lose brush springs.
4. Brush replacement is recommended if brushes are pitted, chipped or worn to less than
0.25 in. (6.4 mm). If necessary, remove brushes as follows:
a. Remove hex nut and washers from POSITIVE (+) terminal and remove POSITIVE
b. Remove 2 bolts securing NEGATIVE (–) brushes and brush holder to end cap.
a -
b -
c -
d -
e -
Page 2B-28
a
Through Bolts
Commutator End Cap
brushes and terminal as an assembly.
b
e
c
Brush Holder
Positive Brushes
Negative Brushes
Positive Terminal
Bolts (fasten negative brushes and holder)
b
a
c
e
b
d
11646
11656
90-883728 JULY 2001

Advertisement

Table of Contents
loading

This manual is also suitable for:

175 efi200 efi150xri175xri200xri0t409000

Table of Contents