POWER TRIM
2. To replace brush card, disconnect spade terminal.
3. Cut crimped brush lead.
4. Remove 2 screws securing brush card to end cap.
a -
b -
c -
5. Install new brush card (BRUSH and SEAL KIT 828714A1).
6. Crimp metal connector onto motor lead and new brush lead.
7. Connect spade connector motor lead to brush card connector.
8. Secure brush card to end cap with 2 screws and lockwashers.
9. Inspect O-ring for cuts and abraisions. Replace O-ring as required (BRUSH and SEAL
KIT 828714A1).
a -
b -
c -
d -
e -
Page 5B-42
a
a
Spade Terminal
Crimped Brush Lead
Screws
c
c
a
a
b
b
Brush Card
Metal Connector
Spade Connector
Screws and Lockwashers
O-ring
c
c
b
b
d
d
e
e
53778