Set/Reset Vertical Tabs In Channels; Select Vertical Tab Channel - TallyGenicom Matrix Printer Programmer's Manual

Tallygenicom matrix printer programmer's manual
Table of Contents

Advertisement

Set/Reset Vertical Tabs in Channels

Select Vertical Tab Channel

Data Structure
ASCII
hex.
dec.
ASCII
hex.
dec.
ASCII
hex.
dec.
Description
Up to 16 vertical tabs for one channel <m> can be set. the number of tab channels m
ranges from 0 to 7. The value of n, given in lines, ranges from 1 to 255.
Channel 0 can be set via ESC B. The default value is m=0.
This command is used to select one of the eight vertical tab channels. The value of m
ranges from 0 to 7.
ESC "b"
<m> <n
>...<n
1
1B
62
<m> <n1>...<n16> 00
27
98
<m> <n1>...<n16> 0
ESC "b"
<m> NUL
1B
62
<m> 00
27
98
<m> 0
ESC "/"
<m>
1B
2F
<m>
27
47
<m>
> NUL
set vertical tabs in channels
16
clear all tab settings
select vertical tab channel
ESC b
ESC /
57
Print Positioning