Festo CPX-AB Series Electronic Manual page 169

Cpx terminal/analogue i/o modules, sub-bases type
Hide thumbs Also See for CPX-AB Series:
Table of Contents

Advertisement

5. Analogue output module CPX−2AA−U−I
Data format VZ + 12 bits right−justified" (compatible with valve terminal type 03)
D15 D14 D13 D12 D11 D10 D9
VZ
0
0
0
Abbreviations used:
VZ:
Sign (with data format VZ + 12 bits right−justified" always = 0, i.e. a positive value)
B0 ... B11:
Output value
D0 ... D15:
16 bits output data field
MSB/LSB:
Most significant bit / least significant bit
Tab. 5/6:
Data format VZ + 12 bits right−justified"
Festo P.BE−CPX−AX−EN en 0503b
Reaction with the default settings
The module parameter Output analogue−value data format"
possesses the default setting VZ + 12 bits right−justified"
(compatible with valve terminal type 03). With this setting the
output words will be output as analogue values as follows:
D8
B11
B10 B9
B8
MSB
The channel−specific parameters Lower limit" and Upper
limit" possess the following default settings:
Lower limit = 0
Upper limit = 4095
These correspond to the scaling end values (data range) of
the default data format.
D7
D6
D5
D4
B7
B6
B5
B4
D3
D2
D1
D0
B3
B2
B1
B0
LSB
5−13