2 T clim mot/gen
3 T lim sym
4 T lim pos/neg
If set to 0 no specific type of current limitation is set.
If set to 1 the active positive torque limit is Torque curr lim Pos and the active negative torque limit is Torque
curr lim Neg; the limit is provided on the torque current.
Torque limits with Torque curr lim Sel = 1
If set to 2 three conditions are possible:
1 - If the motor speed is > +1% of Rated speed the active positive torque limit is Torque curr lim Pos and
the active negative torque limit is Torque curr lim Neg.
2 - If the motor speed is < -1% of Rated speed the active positive torque limit is Torque curr lim Neg and
the active negative torque limit is Torque curr lim Pos.
3 - If -1% of Motor non speed < motor speed < + 1% of Rated speed the active positive torque limit is
Torque curr lim Pos and the active negative torque limit is Torque curr lim Neg
If set to 3 the torque limits are symmetrical. The torque reference is the value of parameter 2358 Torque lim
pos src. This mode is not managed in the V/f control mode. The limit is provided on the torque current.
If set to 4 the torque limits are assigned independently, setting the value of parameter 2358 Torque lim pos
src as the positive torque reference and the value of parameter 2370 Torque lim neg src as the negative
torque reference. The torque reference is the value of parameter 2370 Torque lim neg src. This mode is not
managed in the V/f control mode. The limit is provided on the torque current.
Menu
PAR
Description
20.4
2358 Torque lim pos src
Selection of the origin (source) to be used to set the torque limit:
If parameter 2354 Torque curr lim sel is set to 3 the torque limit is symmetrical
If parameter 2354 Torque curr lim sel is set to 4 the torque limit is positive
The signals that can be associated with the function can be selected from the "L_PLIM" selection list.
ADV200 • Functions description and parameters list
UM
Type
FB BIT
LINK
16/32
Torque limits with Torque curr lim sel = 2
Def
Min
6000
0
Max
Acc
Mod
16384
ERWZ F_S
97