gefran ADV200 Functions Description And Parameters List page 150

Field oriented vector ac drive for asyncronous motors
Hide thumbs Also See for ADV200:
Table of Contents

Advertisement

rameter is a float-type parameter not in real time (5-10ms)
Note !
If the sys parameter is not assigned, none of the subsequent channels are transferred to the fieldbus, even if programmed.
Menu
PAR
Description
23.4.3 4184 Dig Fieldbus S->M1
23.4.7 4194 Dig Fieldbus S->M2
23.4.11 4204 Dig Fieldbus S->M3
23.4.15 4214 Dig Fieldbus S->M4
23.4.19 4224 Dig Fieldbus S->M5
23.4.23 4234 Dig Fieldbus S->M6
23.4.27 4244 Dig Fieldbus S->M7
23.4.31 4254 Dig Fieldbus S->M8
23.4.35 4264 Dig Fieldbus S->M9
23.4.39 4274 Dig Fieldbus S->M10
23.4.43 4284 Dig Fieldbus S->M11
23.4.47 4294 Dig Fieldbus S->M12
23.4.51 4304 Dig Fieldbus S->M13
23.4.55 4314 Dig Fieldbus S->M14
23.4.59 4324 Dig Fieldbus S->M15
23.4.63 4334 Dig Fieldbus S->M16
If associated with the relative src, the value of this parameter is sent to the bus.
The user may modify the M->S and by S->M sys parameters. The consistency of the sys with the parameter
assigned to the channel is checked.
Menu
PAR
Description
23.4.4 4186 Fieldbus S->M1 mul
23.4.8 4196 Fieldbus S->M2 mul
23.4.12 4206 Fieldbus S->M3 mul
23.4.16 4216 Fieldbus S->M4 mul
23.4.20 4226 Fieldbus S->M5 mul
23.4.24 4236 Fieldbus S->M6 mul
23.4.28 4246 Fieldbus S->M7 mul
23.4.32 4256 Fieldbus S->M8 mul
23.4.36 4266 Fieldbus S->M9 mul
23.4.40 4276 Fieldbus S->M10 mul
23.4.44 4286 Fieldbus S->M11 mul
23.4.48 4296 Fieldbus S->M12 mul
23.4.52 4306 Fieldbus S->M13 mul
23.4.56 4316 Fieldbus S->M14 mul
23.4.60 4326 Fieldbus S->M15 mul
23.4.64 4336 Fieldbus S->M16 mul
The "Fieldbus S->Mx mul" parameters are multipliers that the drive applies to the datum before sending it to
the bus. It is therefore possible to increase the resolution of some values read in EU and EU_float mode, also
using decimal digits.
N.B.: The drive does not check that the multiplied parameter expressed in bits fits in a 16-bit integer. You must
make sure that the multiplier is compatible with the maximum value of the exchanged parameter and that it
150
UM
Type
FB BIT
INT32 32
INT32 32
INT32 32
INT32 32
INT32 32
INT32 32
INT32 32
INT32 32
INT32 32
INT32 32
INT32 32
INT32 32
INT32 32
INT32 32
INT32 32
INT32 32
UM
Type
FB BIT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
FLOAT
Def
Min
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Def
Min
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
ADV200 • Functions description and parameters list
Max
Acc
Mod
0
ERW FVS
0
ERW FVS
0
ERW FVS
0
ERW FVS
0
ERW FVS
0
ERW FVS
0
ERW FVS
0
ERW FVS
0
ERW FVS
0
ERW FVS
0
ERW FVS
0
ERW FVS
0
ERW FVS
0
ERW FVS
0
ERW FVS
0
ERW FVS
Max
Acc
Mod
1000.0
ERW FVS
1000.0
ERW FVS
1000.0
ERW FVS
1000.0
ERW FVS
1000.0
ERW FVS
1000.0
ERW FVS
1000.0
ERW FVS
1000.0
ERW FVS
1000.0
ERW FVS
1000.0
ERW FVS
1000.0
ERW FVS
1000.0
ERW FVS
1000.0
ERW FVS
1000.0
ERW FVS
1000.0
ERW FVS
1000.0
ERW FVS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents