B – Parameters and functions description (Expert list)

Legend

  
Menu
PAR
Description
1 - MONITOR
1.1
250 Output current
1.2
252 Output voltage
22.1 - FUNCTIONS/SPEED RATIO
22.1.1 3000 Dig speed ratio
22.1.2
3002 Speed ratio src
Indexing of the menu and parameter
Parameter identifier
Parameter description
UM: unit of measure
Type of parameter
BIT
Boolean, from modbus seen as 16 bits
ENUM
Selection list, from modbus seen as 16 bits
FLOAT
Real, from modbus seen as 32 bits
FBM2SIPA 16-bit unsigned integer. Only PAR of existing
parameters accepted.
FBS2MIPA 16-bit unsigned integer. Only PAR of existing
parameters accepted.
INT16
Integer with sign 16 bits, from modbus seen as 16 bits
INT32
Integer with sign 32 bits, from modbus seen as 32 bits
ILINK
Selection list, from modbus seen as 16 bits
LINK
Selection list, from modbus seen as 16 bits
UINT16
Integer without sign 16 bits, from modbus seen as
16 bits
UINT32
Integer without sign 32 bits, from modbus seen as
32 bits
SINT
Integer 8 bits
Format of data exchanged on Fieldbus (16BIT, 32BIT)
8
 
UM
Type
FB BIT
( Level 1 menu )
A
FLOAT 16/32
V
FLOAT 16/32
( Level 2 menu )
perc
INT16 16/32
LINK
16/32 3000
L_VREF ( Selection List ) [*]
[*]
Def
Min
0.0
0.0
0.0
0.0
100
CALCI
0
CALCF Value calculated as a number with
Default value
floating point
CALCI Value calculated as a whole
Minimum value
number
SIZE
Value depending on the size of the
Maximum value
drive
Accessibility :
E Expert
R Read
S Size (set value depending on the size of the device)
W Write
Z parameters that can be modified ONLY with the drive disa-
bled
Available in regulation mode:
V = V/f Control
S = Vect Flux OL
F = Vect Flux CL
Selection lists:
The "... src" format parameters are linked to a selection list.
The source of the signal that will control the parameter can be
selected from the list indicated.
The lists are indicated in paragraph C of this manual.
ADV200 • Functions description and parameters list
 
Max
Acc
Mod
0.0
R
FVS
0.0
R
FVS
CALCI
ERW FVS
16384
ERW
FVS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents