gefran ADV200 Functions Description And Parameters List page 93

Field oriented vector ac drive for asyncronous motors
Hide thumbs Also See for ADV200:
Table of Contents

Advertisement

Menu
PAR
Description
19.5
2264 Flux reg P gain OL
Setting of the flux regulator proportional gain when the drive is used in open loop sensorless vector control
mode. This parameter is set automatically by the self-tuning procedure.
Menu
PAR
Description
19.6
2266 Flux reg I time OL
Setting of the flux regulator integral time when the drive is used in open loop sensorless vector control mode.
This parameter is set automatically by the self-tuning procedure.
Menu
PAR
Description
19.7
2270 Voltage reg P gain
Setting of the proportional coefficient of the voltage regulator.
Menu
PAR
Description
19.8
2272 Voltage reg I time
Setting of the integral coefficient of the voltage regulator.
The dead time compensation function (Dead time compensation), compensates the distortion of output volt-
age caused by the voltage drop on the IGBT devices and their switching characteristics.
Distortion of output voltage could cause irregular motor rotation.
Menu
PAR
Description
19.9
2280 Dead time limit
Setting of the dead time voltage compensation value.
Menu
PAR
Description
19.10
2282 Dead time slope
Setting of the dead time compensation slope value.
Menu
PAR
Description
19.11
2290 Voltage base
Setting of the voltage value that determines the threshold at which flux weakening starts (maximum drive out-
put voltage). If this parameter is set to a value equal to the nominal speed of the motor, operation is at nominal
flux in the constant torque region and weakened flux at higher frequencies. The default value is set to the volt-
age supply value.
Menu
PAR
Description
19.12
2292 Voltage margin
Setting of the voltage regulation margin according to the available voltage. In case of a Voltage base setting
ADV200 • Functions description and parameters list
UM
Type
FB BIT
A/Wb FLOAT
UM
Type
FB BIT
ms
FLOAT
UM
Type
FB BIT
Wb/V FLOAT
UM
Type
FB BIT
s
FLOAT
Dead time compensation
Output voltage
Voltage command to PWM
Dead time limit
UM
Type
FB BIT
V
FLOAT
UM
Type
FB BIT
V/A
FLOAT
UM
Type
FB BIT
V
FLOAT
UM
Type
FB BIT
perc
FLOAT
Def
Min
CALCF
0.0
Def
Min
CALCF
0.01
Def
Min
CALCF
0.0
Def
Min
CALCF
0.1
Dead time slope
Def
Min
SIZE
0.0
Def
Min
SIZE
0.0
Def
Min
CALCF
50.0
Def
Min
5.0
0.0
Max
Acc
Mod
0.0
ERWS __S
Max
Acc
Mod
10000.0
ERWS __S
Max
Acc
Mod
0.0
ERWS F_S
Max
Acc
Mod
100.0
ERWS F_S
Max
Acc
Mod
50.0
ERWS FVS
Max
Acc
Mod
200.0
ERWS FVS
Max
Acc
Mod
690.0
ERWS F_S
Max
Acc
Mod
10.0
ERWS F_S
93