gefran ADV200 Functions Description And Parameters List page 31

Field oriented vector ac drive for asyncronous motors
Hide thumbs Also See for ADV200:
Table of Contents

Advertisement

Menu
PAR
Description
6.12
726 Multi ramp sel mon
The set of acceleration/deceleration ramps selected using the digital inputs is displayed.
Menu
PAR
Description
6.13
730 Accel jerk time 0
6.14
732 Decel jerk time 0
6.15
734 Accel jerk time 1
6.16
736 Decel jerk time 1
6.17
738 Accel jerk time 2
6.18
740 Decel jerk time 2
6.19
742 Accel jerk time 3
6.20
744 Decel jerk time 3
Jerks are variations of acceleration in time. They are used when there is a need to dampen the beginning and
end of the ramp. The Jerk value is added, regardless of the variation in speed, to the linear ramp time.
f
6.13
ACC TIME
Menu
PAR
Description
6.21
750 Ramp in zero src
Selection of the origin (source) of the signal that blocks the ramp input and moves the reference to zero. If the
ramp input is enabled, the Ramp ref parameter corresponds to the set reference. If the ramp input is blocked,
the drive slows down with the set deceleration time until reaching zero speed. The terminal to be associated
with this function can be selected from the "L_DIGSEL2" selection list.
Menu
PAR
Description
6.22
752 Ramp out zero src
Selection of the origin (source) of the signal that brings the ramp to 0 (Ramp ref 1/Ramp ref 2 = 0). When the
ramp output is set to zero using Ramp out zero, the drive brakes with the maximum available torque; in this
case the ramp is disabled. The terminal to be associated with this function can be selected from the "L_DIG-
SEL2" selection list.
Menu
PAR
Description
6.23
754 Ramp freeze src
Selection of the origin (source) of the signal that temporarily freezes the ramp output value, regardless of any
changes in the input reference. The terminal to be associated with this function can be selected from the "L_
DIGSEL2" selection list.
ADV200 • Functions description and parameters list
UM
Type
FB BIT
UINT16
UM
Type
FB BIT
s
FLOAT
s
FLOAT
s
FLOAT
s
FLOAT
s
FLOAT
s
FLOAT
s
FLOAT
s
FLOAT
6.13
6.14
DEC TIME
UM
Type
FB BIT
LINK
16
UM
Type
FB BIT
LINK
16
UM
Type
FB BIT
LINK
16
Def
Min
0
0
Def
Min
1.0
0.02
1.0
0.02
1.0
0.02
1.0
0.02
1.0
0.02
1.0
0.02
1.0
0.02
1.0
0.02
6.14
t
Def
Min
6000
0
Def
Min
6000
0
Def
Min
3480
0
Max
Acc
Mod
3
ER
FVS
Max
Acc
Mod
10.0
ERW FVS
10.0
ERW FVS
10.0
ERW FVS
10.0
ERW FVS
10.0
ERW FVS
10.0
ERW FVS
10.0
ERW FVS
10.0
ERW FVS
Max
Acc
Mod
16384
ERW FVS
Max
Acc
Mod
16384
ERW FVS
Max
Acc
Mod
16384
ERW FVS
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents