7 Output & ref = 0
8 Output & ref = low lim
9 Input = upp lim
10 Input & ref = upp lim
11 Freeze input
When set to None, no setting is executed.
Input = 0 sets input = 0 i.e. a temporary reference setting is performed and the previous reference value is
maintained. The output of the Motor potentiometer function varies with the set ramp times. The previous refer-
ence value is restored when the preset command is removed.
Input = low lim sets Inp = low lim i.e. a temporary reference setting is performed and the previous reference
value is maintained. The output of the Motor potentiometer function varies with the set ramp times. The previ-
ous reference value is restored when the preset command is removed.
Input & ref = 0 sets Inp = 0 and Ref = 0 i.e. a definitive reference setting is performed. The output of the Motor
potentiometer function varies with the set ramp times.
Input & ref = low lim sets Inp = low lim and Ref = low lim i.e. a definitive reference setting is performed. The
output of the Motor potentiometer function varies with the set ramp times.
Output = 0 sets Out = 0 i.e. a temporary output setting for the Motor potentiometer function is performed. The
previous reference value is maintained. If the preset command is enabled, the output of the Motor potentiom-
eter function continues to be = 0, if the preset command is not enabled the output of the Motor potentiometer
function varies with the set ramp times.
Output = low lim sets Out = low lim i.e. a temporary setting for the output of the Motor potentiometer function
is performed. Il precedente valore di riferimento viene mantenuto .The previous reference value is maintained.
If the preset command is enabled, the output of the Motor potentiometer function continues to be = low lim,
if the preset command is not enabled the output of the Motor potentiometer function varies with the set ramp
times.
Output & ref = 0 sets Out = 0 i.e. a definitive setting for the output of the Motor potentiometer function is per-
formed.
Output & ref = low lim sets Out = low lim i.e. a definitive setting for the output of the Motor potentiometer func-
tion is performed.
Input = upp lim sets Inp = upp lim i.e. a temporary setting for the reference is performed and the previous ref-
erence value is maintained. The output of the Motor potentiometer function varies with the set ramp times. The
previous reference value is restored when the preset command is removed.
Input & ref = upp lim sets Inp = upp lim and Ref = upp lim i.e. a definitive reference setting is performed. The
output of the Motor potentiometer function varies with the set ramp times.
When Freeze input is set, the Up and Down commands are temporarily disabled.
Menu
PAR
Description
8.8
884 Mpot up src
Selection of the origin (source) of the signal that increases the speed reference of the motor potentiometer with
the set ramp. The terminal to be associated with this function can be selected from the "L_DIGSEL2" selection
list.
Menu
PAR
Description
8.9
886 Mpot down src
Selection of the origin (source) of the signal that decreases the speed reference of the motor potentiometer
with the set ramp. The terminal to be associated with this function can be selected from the "L_DIGSEL2"
selection list.
Menu
PAR
Description
8.10
888 Mpot invert src
Selection of the origin (source) of the signal that inverts the speed reference of the motor potentiometer. The
38
UM
Type
FB BIT
LINK
16
UM
Type
FB BIT
LINK
16
UM
Type
FB BIT
LINK
16
Def
Min
6000
0
Def
Min
6000
0
Def
Min
6000
0
ADV200 • Functions description and parameters list
Max
Acc
Mod
16384
RW
FVS
Max
Acc
Mod
16384
RW
FVS
Max
Acc
Mod
16384
ERW FVS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents