Parameters On Selection Lists, But Not Displayed On Keypad - gefran ADV200 Functions Description And Parameters List

Field oriented vector ac drive for asyncronous motors
Hide thumbs Also See for ADV200:
Table of Contents

Advertisement

PARAMETERS ON SELECTION LISTS, BUT NOT DISPLAYED ON KEYPAD
Menu
PAR
Description
220 Theta ref mon
Monitor value of the electrical motor angle.
Menu
PAR
Description
224 Flux ref mon
Monitor value of the Flux reference.
Menu
PAR
Description
262 Motor speed nofilter
This parameter indicates the unfiltered motor speed.
Menu
PAR
Description
362 Drive overload trip
This signal indicates that the drive is in the overload condition. In the default condition the alarm is not triggered
as the relative action is set to Ignore.
Menu
PAR
Description
366 Drive overload 80
This signal indicates that the drive has reached 80% of the thermal image accumulator (drive overload).
Menu
PAR
Description
626 Ramp ref out mon
This parameter displays the reference value output of the ramp remference function block.
Menu
PAR
Description
760 Ramp out mon
This parameter displays the reference value output of the ramp function block.
Menu
PAR
Description
764 Ramp acc state
This signal indicates whether the acceleration ramp is active.
Menu
PAR
Description
766 SRamp dec state
This signal indicates whether the deceleration ramp is active.
Menu
PAR
Description
934 Ref is 0
This signal is active when the reference is below the limit set in parameter 930 Reference 0 threshold.
Menu
PAR
Description
936 Ref is 0 delay
This parameter is active when the reference is below the threshold set in parameter 930 Reference 0 thresh-
old. The signal is enabled after the delay set with parameter 932 Reference delay 0.
Menu
PAR
Description
944 Speed is 0
170
UM
Type
FB BIT
INT32
UM
Type
FB BIT
INT32
UM
Type
FB BIT
FF
INT16 16
UM
Type
FB BIT
BIT
16
UM
Type
FB BIT
BIT
16
UM
Type
FB BIT
FF
INT16 16
UM
Type
FB BIT
FF
INT16 16
UM
Type
FB BIT
BIT
16
UM
Type
FB BIT
BIT
16
UM
Type
FB BIT
BIT
16
UM
Type
FB BIT
BIT
16
UM
Type
FB BIT
BIT
16
Def
Min
0.0
0.0
Def
Min
0.0
0.0
Def
Min
0
0
Def
Min
0
0
Def
Min
0
0
Def
Min
0
0
Def
Min
0
0
Def
Min
0
0
Def
Min
0
0
Def
Min
0
0
Def
Min
0
0
Def
Min
0
0
ADV200 • Functions description and parameters list
Max
Acc
Mod
0.0
ER
Max
Acc
Mod
0.0
ER
Max
Acc
Mod
0
ER
Max
Acc
Mod
1
ER
Max
Acc
Mod
1
ER
Max
Acc
Mod
0
ER
Max
Acc
Mod
0
ER
Max
Acc
Mod
1
ER
Max
Acc
Mod
1
ER
Max
Acc
Mod
1
ER
Max
Acc
Mod
1
ER
Max
Acc
Mod
1
ER

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents