gefran ADV200 Functions Description And Parameters List page 155

Field oriented vector ac drive for asyncronous motors
Hide thumbs Also See for ADV200:
Table of Contents

Advertisement

Menu
PAR
Description
23.8.6 5714 FL fault enable src
This parameter is used to select the origin (source) of the FL fault enable signal.
The signal to be associated with this function can be selected from the "L_DIGSEL1" selection list.
0 FL fault enable not active (No FastLink alarm signal)
1 FL fault enable active (FastLink alarm signal)
When the drive detects a FastLink fault, it prepares to trigger a "FastLink fault" alarm.
This command is used to select whether an alarm is generated when a fault is detected.
Alarm generation is enabled in the default configuration.
The configuration of the "FL fault enable src" parameter can be changed to control the phases in which alarm
generation is enabled.
For example, by connecting the "FL fault enable src" parameter to "Enable state mon" you can enable gen-
eration of the "FastLink fault" alarm in the phase when the drive is enabled.
In systems where drive the drives are not powered-off simultaneously, some drives detect a FastLink fault and
generate a FastLink alarm.
This parameter is used to disable the alarm at power-off by connecting the "FL fault enable src" parameter to
"Enable state mon".
Menu
PAR
Description
23.8.7 5730 FL Fwd 1 src
23.8.8 5732 FL Fwd 2 src
23.8.9 5734 FL Fwd 3 src
23.8.10 5736 FL Fwd 4 src
This parameter is used to select the origin (source) of the FL Fw 1 src signal.
The signal to be associated with this function can be selected from the "L_FLWORD" selection list.
On the drive configured as the master, these parameters are used to select the data to be sent to the first
slave.
On drives configured as slaves, these paramters are used to select the data that the slave must include in the
data frame to replace the data received from the previous drive.
Replacement is disabled in the default configuration. It can be enabled with the PAR 5712 "FL N Fwd slave
chg" parameter.
Menu
PAR
Description
23.8.11 5830 FL Rev 1 src
23.8.12 5832 FL Rev 2 src
Parameter significant only for Slave drive, indicates what data to insert in first word to be sent to Master drive
when Slave is interrogated. Selectable values are shown on the L_FLWORD list.
Menu
PAR
Description
23.8.13 5750 FL Fwd 1 mon
23.8.14 5752 FL Fwd 2 mon
23.8.15 5754 FL Fwd 3 mon
23.8.16 5756 FL Fwd 4 mon
23.8.17 5758 FL Fwd 5 mon
23.8.18 5760 FL Fwd 6 mon
23.8.19 5762 FL Fwd 7 mon
23.8.20 5764 FL Fwd 8 mon
These parameters are not used on the master drive.
On the slave drive these parameters show the value received from the previous drive. The "Inv" parameters en-
able the value received to be used with the opposite sign, without changing any of the data sent to subsequent
slaves.
ADV200 • Functions description and parameters list
UM
Type
FB BIT
LINK
16
UM
Type
FB BIT
LINK
16/32BIT
LINK
16/32BIT
LINK
16/32BIT
LINK
16/32BIT
UM
Type
FB BIT
LINK
16/32BIT
LINK
16/32BIT
UM
Type
FB BIT
INT32 32BIT
INT32 32BIT
INT32 32BIT
INT32 32BIT
INT32 32BIT
INT32 32BIT
INT32 32BIT
INT32 32BIT
Def
Min
6002
0
Def
Min
6000
0
6000
0
6000
0
6000
0
Def
Min
6000
0
6000
0
Def
Min
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Max
Acc
Mod
16384
ERW FVS
Max
Acc
Mod
16384
ERW FVS
16384
ERW FVS
16384
ERW FVS
16384
ERW FVS
Max
Acc
Mod
16384
ERW FVS
16384
ERW FVS
Max
Acc
Mod
2^32
ER
FVS
2^32
ER
FVS
2^32
ER
FVS
2^32
ER
FVS
2^32
ER
FVS
2^32
ER
FVS
2^32
ER
FVS
2^32
ER
FVS
155