PAR
Description
24.58
4704 Alarm dig sel 3
ADV200 • Parameters List
UM
Type
FB BIT Def
58
Plc14 fault
59
Plc15 fault
60
Plc16 fault
ENUM
0
No alarm
1
Overvoltage
2
Undervoltage
3
Ground fault
4
Overcurrent
5
Desaturation
6
MultiUndervolt
7
MultiOvercurr
8
MultiDesat
9
Heatsink OT
10
HeatsinkS OTUT
11
Intakeair OT
12
Motor OT
13
Drive overload
14
Motor overload
15
Bres overload
16
Phaseloss
17
Opt Bus fault
18
Opt 1 IO fault
19
Opt 2 IO fault
20
Opt Enc fault
21
External fault
22
Speed fbk loss
23
Overspeed
24
Speed ref loss
25
Emg stop alarm
26
Power down
27
ExtIO fault
28
FastLink fault
29
Brake fault
30
Motor pre OT
31
Mot phase loss
32
Not Used2
33
Plc1 fault
34
Plc2 fault
35
Plc3 fault
36
Plc4 fault
37
Plc5 fault
38
Plc6 fault
39
Plc7 fault
40
Plc8 fault
41
Watchdog
42
Trap error
43
System error
44
User error
45
Param error
46
Load def par
47
Plc cfg error
48
Load def plc
49
Key failed
50
Encoder error
51
Opt cfg change
Min
Max
No alarm
0
60
Acc
Mod
ERW
FVS
261

Hide quick links:

Advertisement

Table of Contents
loading