gefran ADV200 Functions Description And Parameters List page 68

Field oriented vector ac drive for asyncronous motors
Hide thumbs Also See for ADV200:
Table of Contents

Advertisement

Note !
The value that is obtained automatically can be changed manually, if necessary, using An inp offset xX.
If the voltage setting on the analog input is higher than 1V, the Value too low alarm is generated.
Menu
PAR
Description
14.37
1608 An inp 1X gain tune
14.48
1658 An inp 2X gain tune
Self-tuning command for the relative analog input gain. Automatic fine tuning of the input. When this command
is sent, Analog inp 1 gain x is automatically selected so that the available input signal corresponds to the
maximum value of the variable.
Two conditions are necessary in order to perform automatic tuning:
- Input voltage greater than 1V or input current greater than 2 mA
- Positive polarity. The value that is found is automatically accepted for the other direction of rotation.
Note !
If necessary, the value obtained automatically can be changed manually via Analog inp Xx gain.
To perform self-tuning, set the input signal to its maximum value and execute the command. A multiplier factor
is calculated to apply to the input signal value (not considering the Analog inp scale parameter) to reach the
full scale value.
If the voltage setting on the analog input is less than 1V, the Value too low alarm is generated.
Menu
PAR
Description
14.38
1612 Analog inp 1X top
14.49
1662 Analog inp 2X top
Setting of the upper speed reference limit as a function of the voltage (or current) of the relative analog refer-
ence of the expansion card.
Menu
PAR
Description
14.39
1614 Analog inp 1X bottom
14.50
1664 Analog inp 2X bottom
Setting of the lower speed reference limit as a function of the voltage (or current) of the relative analog refer-
ence of the expansion card.
Menu
PAR
Description
14.40
1616 Analog inp 1X offset
14.51
1666 Analog inp 2X offset
Setting of an offset value to algebrically add to the relative analog input of the expansion card.
Menu
PAR
Description
14.41
1618 Analog inp 1X gain
14.52
1668 Analog inp 2X gain
68
UM
Type
FB BIT
BIT
BIT
UM
Type
FB BIT
cnt
INT16
cnt
INT16
UM
Type
FB BIT
cnt
INT16
cnt
INT16
UM
Type
FB BIT
cnt
INT16
cnt
INT16
100%
{
Analog inp xX offset
0
UM
Type
FB BIT
FLOAT
FLOAT
Def
Min
0
0
0
0
Def
Min
16384
-32768
16384
-32768
Def
Min
-16384
-32768
-16384
-32768
Def
Min
0
-32768
0
-32768
10V
Def
Min
1.0
-20.0
1.0
-20.0
ADV200 • Functions description and parameters list
Max
Acc
Mod
1
RWZ FVS
1
RWZ FVS
Max
Acc
Mod
+ 32767
ERW FVS
+ 32767
ERW FVS
Max
Acc
Mod
+ 32767
ERW FVS
+ 32767
ERW FVS
Max
Acc
Mod
+ 32767
ERW FVS
+ 32767
ERW FVS
Max
Acc
Mod
20.0
ERW FVS
20.0
ERW FVS