Quantum F2000 User Manual page 190

Hide thumbs Also See for F2000:
Table of Contents

Advertisement

Chapter 4: F2000 Customer Replaceable Units (CRUs)
SSD Assembly Replacement
Figure 189 LED Location on an
SSD Assembly (Drive in Slot 01
Shown)
176
If the drive has lost power or is missing, the system will return the
following message:
No action taken for detach request
Keep the SSH connection to the Appliance Controller Console open
because you will need when performing
page 178.
3 Go to the front of the F2000 and remove the bezel, if necessary.
4 Locate the degraded drive using the drive slot location provided in
the StorNext RAS ticket. Confirm that the degraded drive's LEDs
show the following activity:
• Drive Fault LED is solid or blinking amber
• Drive Link/Active LED is NOT blinking green
See
Figure 189
for drive LED locations.
Note: Refer to
Identify a Degraded SSD
additional details on how to identify a degraded drive.
Item
LED
1
Drive Fault
Install an SSD Assembly
on page 173 for
Action
Amber (solid or blinking): Degraded
drive reported. Replace the SSD.
Quantum F2000 User's Guide
on

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents