Quantum F2000 User Manual page 87

Hide thumbs Also See for F2000:
Table of Contents

Advertisement

Figure 58 IPMI/BMC Port
Location on the Top Canister
Quantum F2000 User's Guide
Item
LED
2
Canister
Fault
6 Disconnect the CAT6A Ethernet cable from the IPMI/BMC port on
the canister.
7 Connect the CAT6A Ethernet cable to the IPMI/BMC port on the
bottom canister (see
Item
1
IPMI/BMC port on the top canister
8 Repeat
Step 2
on page 70 through
canister.
Disconnect the Cables from the System
To disconnect the cables:
1 At the rear of the system, locate the PSU A and PSU B receptacles
(see
Figure 59
on page 74).
Chapter 4: F2000 Customer Replaceable Units (CRUs)
Action
Amber solid: Fault conditions in canister exist
Figure
58).
Description
Step 6
Chassis Replacement
to power off the bottom
73